... attributed to the misalignment of the sling during loading. Aluminum alloy 5183 or 5356 filler metal was recommended to be used to avoid brittle welds. Alignment Cranes Filler metal Welded joints 5083 UNS A95083 5086 UNS A95086 Joining-related failures Brittle fracture The T-section cross...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.process.c9001589
EISBN: 978-1-62708-235-8
... above the plating line were blown into the plating tank and getting co-deposited. The paper describes the step-by-step analysis of the defect that led to successful identification of the root cause of the defect. Coatings Defect analysis Fibers 5086 UNS A95086 Ni-11P Surface treatment...