Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.mech.c0047710
EISBN: 978-1-62708-225-9
... Abstract A 9310 steel gear was found to be defective after a period of engine service. A linear crack approximately was discovered by routine magnetic-particle inspection of an electron beam welded joint that attached a hollow stub shaft to the web of the gear. The welding procedure had...
Image
Published: 01 January 2002
Fig. 20 Highway-truck equalizer beam, sand cast from low-alloy steel, that fractured because of mechanical cracking. (a) Fracture surface; detail A shows increments (regions B, C, D, and E) in which crack propagation occurred sequentially. Dimensions given in inches. (b) Micrograph More
Image
Published: 01 January 2002
Fig. 58 Gas porosity in electron beam welds of low-carbon steel and titanium alloy. (a) Gas porosity in a weld in rimmed AISI 1010 steel. Etched with 5% nital. 30×. (b) Massive voids in weld centerline of 50 mm (2 in.) thick titanium alloy Ti-6Al-4V. 1.2× More
Image
Published: 30 August 2021
Fig. 55 Fracture surface of an electron beam weld in the web of an AISI 9310 steel gear. The weld fractured because of incomplete fusion. The incomplete fusion zone where fracture originated is shown at region A; region B shows fatigue beach marks, and region C exhibits bending fatigue More
Image
Published: 01 June 2019
Fig. 1 Highway-truck equalizer beam, sand cast from low-alloy steel, that fractured because of mechanical cracking. (a) Fracture surface; detail A shows increments (regions B, C, D, and E) in which crack propagation occurred sequentially. Dimensions given in inches. (b) Micrograph More
Image
Published: 01 June 2019
Fig. 1 Fracture surface of an electron beam weld in the web of an AISI 9310 steel gear. The weld fractured because of incomplete fusion. The incomplete-fusion zone where fracture originated is shown at region A; region B shows fatigue beach marks, and region C exhibits bending-fatigue patterns More
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.auto.c0089572
EISBN: 978-1-62708-218-1
... Abstract Two sand-cast low-alloy steel equalizer beams (ASTM A 148, grade 105-85) designed to distribute the load to the axles of a highway truck broke after an unreported length of service. Normal service life would have been about 805,000 km (500,000 mi) of truck operation. Investigation...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.rail.c0048087
EISBN: 978-1-62708-231-0
... Abstract Several of the welds in a hoist carriage tram-rail assembly fabricated by shielded metal arc welding the leg of a large T-section 1020 steel beam to the leg of a smaller T-section 1050 steel rail failed in one portion of the assembly. Four weld cracks and several indefinite indications...
Image
Published: 01 January 2002
Fig. 4 Relation of distortion ratio to stress ratio for two steel cantilever beams of rectangular cross section. Distortion ratio is permanent deflection, measured at a distance from the support ten times the beam thickness, divided by beam thickness. Stress ratio is maximum stress, calculated More
Image
Published: 15 January 2021
Fig. 4 Relation of distortion ratio to stress ratio for two steel cantilever beams of rectangular cross section. Distortion ratio is permanent deflection, measured at a distance from the support ten times the beam thickness, divided by beam thickness. Stress ratio is maximum stress, calculated More
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c9001702
EISBN: 978-1-62708-219-8
... survey, potential and corrosion mapping, concrete chemistry, and concrete physical properties. The major cause of corrosion damage appears to have been the presence of both pre-existing and environmentally-delivered chlorides in the concrete. Bridges Cements Chlorides Support beams Steel beam...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0001821
EISBN: 978-1-62708-180-1
..., the stringers framed into the floor beam. References References 1. Fisher J.W. , Fatigue and Fracture in Steel Bridges , Wiley-Interscience , 1984 2. Fisher J.W. and Mertz D.R. , Hundreds of Bridges—Thousands of Cracks , Civil Eng. , April 1985 3. Fisher J.W...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c9001706
EISBN: 978-1-62708-217-4
... in Figures 1 and 2 and 3 . The truck beam was manufactured from high strength 4340 steel alloy. It had logged up to 37329.2 hours in service (TSN) and 1111.5 hours since overhaul (TSO) in 1991. Fig. 1 A view of the fractured truck beam of the main landing gear (MLG) at the site of failure...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.process.c0059924
EISBN: 978-1-62708-235-8
... Abstract The large steel ring produced for a nuclear application from a billet of 8822 steel was inspected. The large billet was first forged into a doughnut preform in a large press, and then formed into the ring by ring rolling. A straight-beam ultrasonic inspection was instituted...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c9001731
EISBN: 978-1-62708-217-4
... discrepancies in the beam. A metallographic examination showed that the steel in the vicinity of the fracture origin had a normal tempered martensitic structure with no indication of surface decarburation. A microhardness survey gave uniform values from the surface inward. A metallographic examination...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c9001656
EISBN: 978-1-62708-219-8
... Abstract Some corrosion processes in the presence of chlorides, for steel embedded in concrete, are described and illustrated with the aid of scanning electron microscope EDXA data. Observations made of failure surfaces of reinforcements removed from the concrete beams after being subjected...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001112
EISBN: 978-1-62708-214-3
... × 150 × 10 mm (17.7 × 5.9 × 0.4 in.), and a beam length of 12.41 m (40.7 ft) ( Fig. 1 ). The beam was made ofcarbon steel with the following maximum specified composition: 0.23% °C, 0.055% S, and 0.055% P Mechanical property specifications were: yield strength, ∼255 MPa (37 ksi); ultimate tensile...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.process.c0047148
EISBN: 978-1-62708-235-8
... Abstract A connecting rod (forged from 15B41 steel and heat treated to a hardness of 29 to 35 HRC) from a truck engine failed after 73,000 Km (45,300 mi) of service. A piece of the I-beam sidewall of the rod, about 6.4 cm (2 in.) long, was missing when the connecting rod arrived at a laboratory...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.conag.c9001588
EISBN: 978-1-62708-221-1
... ductility direction of the transition joint plate, lamellar tearing of plate material occurred at the boxed I-beam fillet weld attachment. Brittle fracture of this joint precipitated global collapse of the truss structure. Bridges (structures) Ore conveyors Structural steel Brittle fracture...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.auto.c0047521
EISBN: 978-1-62708-218-1
... Abstract A supplementary axle, which was used as an extension to a highway-trailer tractor to increase its load-bearing capacity, failed in service. The rolled steel channel extensions that secured the axle assembly to the tractor main-frame I-beams fractured transversely, with the crack...