Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c0091201
EISBN: 978-1-62708-219-8
... Abstract Type 316L (UNS S31603) austenitic stainless steel piping was installed as part of a storm-sewer treatment collection system in a manufacturing facility. Within six months of start-up, leaks were discovered. Investigation (on-site current flow testing, visual inspection, water tests...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003549
EISBN: 978-1-62708-180-1
... a collection system for a storm sewer treatment system used in a manufacturing facility. Within six months of start-up, leaks were discovered. A series of tests were performed on site to eliminate stray currents as a possible cause of failure in the piping system. The piping system was...
Book Chapter

Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003548
EISBN: 978-1-62708-180-1
... reaction is referred to as couple action, and the electrically coupled system is known as a galvanic cell. The couple consists of an anode (which liberates electrons and corrodes typically by metal dissolution and/or metal oxide formation) and a cathode (which gains electrons and typically liberates...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006783
EISBN: 978-1-62708-295-2
... galvanic current flows between them because of the inherent electrical potential difference between the two. The resulting reaction is referred to as couple action, and the electrically coupled system is known as a galvanic cell. The dissimilar metals/materials couple consists of an anode (which liberates...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006782
EISBN: 978-1-62708-295-2
... allows performing the test. When the ring crush test is not possible (if the pipe is already cracked), a Talbot strip test can be performed to obtain the modulus of rupture. These tests are generally performed to get an idea of the overall condition of pipes in water, sewer, and gas service. After...