1-20 of 51 Search Results for

SEM/EDX analysis

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001795
EISBN: 978-1-62708-241-9
... it to uneven or eccentric loading. This explains the preferential nature of the flaking on the outer race and points to an assembly error as the root cause of failure. ball bearing spalling improper installation steel flaking SEM/EDX analysis load distribution AFNOR 100C6 (chromium alloy bearing...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001029
EISBN: 978-1-62708-214-3
...)126×. Fig. 6 SEM micrograph showing a typical brittle overload fracture observed in a failed actuator casting. 315×. Energy-Dispersive X-ray (EDX) Microprobe Analysis The fracture surfaces in the areas where the hot tear defects originated and in the brittle overload areas were...
Image
Published: 01 June 2019
Fig. 3 EPMA analysis of inclusion stringers in failed extrusion press. (a) SEM micrograph of metallographic section near bleed hole. Note large inclusions. 490x. (b) EDX dot map of manganese. (c) EDX dot mop of sulfur More
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.med.c9001573
EISBN: 978-1-62708-226-6
... located in the uncoated area of the wires. Observations and Results The uncoated area of the wire, is the area where the wire is fixtured in the coating chamber during coating. Examination and analysis of the pits (shown in Figure 1 ) using SEM/EDX detection unit revealed significant peaks of B, O...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001084
EISBN: 978-1-62708-214-3
... the allowable tolerances, while the manganese level is just below. Surface examination Energy-dispersive x-ray (EDX) analysis was performed using the SEM to obtain qualitative compositional information. Analyses were performed on the primary fracture surface, the shroud surface, and the surface...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001118
EISBN: 978-1-62708-214-3
.... (a) Inclusions. As polished. 315×. (b) Microstructure. 63×. Chemical Analysis/Identification Energy-dispersive X-ray (EDX) analysis of the base metal revealed the typical type 302 stainless steel alloy composition ( Fig. 11 ). Several inclusions were evident in the cross-sectioned material; EDX...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.machtools.c0045903
EISBN: 978-1-62708-223-5
.... Analysis of the stringers using the SEM/EDX system revealed high concentrations of sulfur and manganese, indicating the presence of manganese sulfide inclusions ( Fig. 3a to c ). No other unusual microconstituents were observed. Fig. 3 EPMA analysis of inclusion stringers in failed extrusion press...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001387
EISBN: 978-1-62708-215-0
... was also present on the bottom or the cell. SEM/EDX studies of the outer and inner surfaces of the gouged anode showed the presence of iron globules at the interface between the gouged and the unattacked anode. The chemical composition of the black powder was determined to be primarily iron. Cell...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001848
EISBN: 978-1-62708-241-9
... and macroscopic inspection, metallographic and chemical analysis, SEM imaging, optical profilometry, mechanical property testing, and EDX analysis. The die was made of chromium hot-work tool steel and the forgings were made of CuZn39Pb3 heated to an initial working temperature 700 deg C. The entire surface...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001267
EISBN: 978-1-62708-215-0
... All the samples were examined in an SEM equipped with an energy-dispersive x-ray (EDX) microprobe. Metallographic cross sections were also prepared in the longitudinal direction through the origin on the ends of four broken spring samples Surface Examination Scanning Electron Microscopy...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001126
EISBN: 978-1-62708-214-3
... oxide and covered on the back surfaces with an adherent black polyethylene plastic. Macro fractography, SEM fractography, EDX analysis, and photo elasticimetry were conducted on four of the shattered panels. Small nickel sulfide inclusions were found at the failure origins. Failure of the panels...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001310
EISBN: 978-1-62708-215-0
... that was being used to condense steam from a nuclear power plant and had been in operation for less than 2 years. Cooling was done with river water. Specimen Selection One failed tube was submitted for failure analysis. The specimens were cut to suit the stage of the scanning electron microscope (SEM...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.process.c0045918
EISBN: 978-1-62708-235-8
.... EDX analysis showed they consisted of niobium and fluorine. Plastic replicas, prepared by standard TEM techniques, were analyzed with selected-area electron diffraction, showing a pattern match for niobium tetrafluoride. Auger analyses showed electron spectra containing peaks representing carbon...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c9001706
EISBN: 978-1-62708-217-4
... confirmed that aluminium-containing pigment was applied on top of manganese phosphate primer to protect then the inner and outer surface of the beam. Fig. 17 SEM micrograph showing the locations used to generate EDX spectra to identify the constituents of the residue in the pit. 20× Fig. 18...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001792
EISBN: 978-1-62708-241-9
... fracture rotary-bending fatigue steel ratchet marks beach marks star-shaped fracture pattern SEM/EDX analysis fatigue strength SAE 4340 (nickel-chromium-molybdenum alloy steel) UNS G43400 SAE 5046H (low-alloy chromium steel) UNS H50460 Introduction The primary objective...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001028
EISBN: 978-1-62708-214-3
... fracture in the root of the weld at the junction of the two sheets ( Fig. 13 , 14 , 15 ). SEM/EDX (energy-dispersive X-ray) analysis showed that this area contained some weld shrinkage ( Fig. 13 and 16 ), some nonmetallic inclusions ( Fig. 14 , 17 , and 18 ), and several areas of ductile dimples...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001833
EISBN: 978-1-62708-241-9
... significant amounts of chromium and carbon ( Fig. 4a ) compared with the chromium and carbon contents on a typical area of grain boundaries ( Fig. 4b ). The SEM observation combined with EDX indicates that the microstructure of the steam chest material is primarily ferrite with granular, chrome-rich carbides...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001774
EISBN: 978-1-62708-241-9
... were largely obliterated. SEM examination, however, showed the presence of large number of secondary cracks on the fracture surfaces ( Fig. 5 ). Compositional analysis carried out by using energy dispersive X-ray (EDX) analyzer attached to the SEM revealed that the corrosion products consisted...
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001845
EISBN: 978-1-62708-241-9
... The aim of the present investigation is to identify the root cause of failure and propose corrective measures. Visual inspection, scanning electron microscopy (SEM) equipped with an energy-dispersive X-ray (EDX) spectrometer for fractographic and microstructural evaluation, along with chemical analysis...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.process.c9001492
EISBN: 978-1-62708-235-8
..., perpendicular to the lead length, were observed with corrosion products/oxides in the crack. Some areas with flaked plating were also observed. SEM examination and EDX/WDX analyses showed the corrosion products to be oxides and chlorides of copper. Cross-section of the leads were metallographically prepared...