1-20 of 27 Search Results for

Fire retardants

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c9001548
EISBN: 978-1-62708-219-8
... Chlorides Fire retardants Plywood 3006-H16 UNS A93006 3105 UNS A93105 Intergranular corrosion Introduction Articles on failure analysis generally fall into two categories: either a description of how to conduct a failure analysis, or a series of case studies of typical failures, usually...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.a0006914
EISBN: 978-1-62708-395-9
... material: modifying or substituting the basic polymer so that exposure to heat and oxygen will not produce rapid combustion, and using flame-retardant additives. It also provides an overview of the burning process and presents two flammability test methods. combustion properties fire resistance...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c9001558
EISBN: 978-1-62708-217-4
... ). Furthermore, the effects of crack growth rate retardation or enhancement caused by prior high or low loads, respectively ( 9 ), have not been systematically accounted for. Nevertheless, the degree of agreement satisfactorily supports the overall hypothesis that C1 and F1 occurred before the fire and C2 and F2...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.marine.c0091394
EISBN: 978-1-62708-227-3
... Abstract An austenitic stainless steel (type 316/316L stainless steel, schedule 40, 64 mm (2.5 in.) diam and larger) piping network used in the fire-sprinkler system in a large saltwater passenger and car ferry failed by rapid leaking. Operating conditions involved stagnant seawater at ambient...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.a0006939
EISBN: 978-1-62708-395-9
... the processability window, shelf life, appearance, flame retardancy, and other properties required to fulfill the application of the material. For example, one of the most-used polyolefin materials, polypropylene, would not be commercially successful without additives, because it is likely to degrade within one week...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001024
EISBN: 978-1-62708-214-3
... of the main rotor blades was found about a mile from the crash site, indicating that it separated in the air. Applications Because this helicopter was designed for use by the U.S. military, its survivability under hostile fire was a design concern. The main rotor blade was designed to withstand hits...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0001816
EISBN: 978-1-62708-180-1
... analysis fatigue fire-side corrosion power plants stress-corrosion cracking tube rupture water-side corrosion FAILURES IN BOILERS and other equipment in stationary and marine power plants that use steam as the working fluid are discussed in this article. The discussion is mainly concerned...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006825
EISBN: 978-1-62708-329-4
... in the superheater or reheater section will be too hot and an overheating failure in the superheater or reheater may occur. Uneven firing of a multiburner furnace can cause a similar effect, especially when furnace conditions do not favor high turbulence of the flue gases. Fireside and Waterside Deposits...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006802
EISBN: 978-1-62708-329-4
... assessments, corrosion assessments, and blast, fire, and heat damage assessments. blast assessment brittle fracture assessment corrosion assessment elevated temperature life assessment failure prevention fatigue life assessment fire assessment fitness-for-service life assessment heat damage...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.a0006925
EISBN: 978-1-62708-395-9
.... They can be grouped into two main categories: those that modify the characteristics of the base polymer by physical means, including plasticizers, lubricants, impact modifiers, fillers, and pigments; and those that achieve their effect by chemical reactions, including flame retardants, stabilizers...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.a0006942
EISBN: 978-1-62708-395-9
... properties. A similar example would be failing to specify that the material needs to contain a flame retardant and placing the product in an application in which the potential for fire is present and life safety might be endangered. Manufacturing Process Improper selection of the manufacturing process...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006778
EISBN: 978-1-62708-295-2
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003543
EISBN: 978-1-62708-180-1
... , London , 1970 • French D.N. , Metallurgical Failures in Fossil Fired Boilers , 2nd ed. , John Wiley & Sons , 1993 • Gibala R. and Hehemann R.F. , Ed., , Hydrogen Embrittlement and Stress Corrosion Cracking , American Society for Metals , 1984 • Linnert...
Series: ASM Handbook
Volume: 11B
Publisher: ASM International
Published: 15 May 2022
DOI: 10.31399/asm.hb.v11B.a0006909
EISBN: 978-1-62708-395-9
... relaxation. After prolonged exposure, certain polymeric systems undergo weight loss through chemical degradation of the polymer, caused by decomposition of the low-molecular-weight constituents such as fillers and additives (catalysts, hardeners, pigments, or fire retardants), resulting in chemical leaching...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0001817
EISBN: 978-1-62708-180-1
..., hydrogen sulfide, carbon dioxide, and ammonia can be very corrosive environments. Another cause of inadvertent general corrosion is improper chemical cleaning using uninhibited acids, excessive temperatures, or prolonged contact time. Water used to wash fire-side deposits where high-sulfur fuel oil...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006783
EISBN: 978-1-62708-295-2
... of anions or cations on the surface of either electrode. This condition is irreversible without external action. This change acts as a retardant to the electrical current flow. Electron flow occurs between metals or alloys in a galvanic couple. This current flow between the more active and more noble...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003512
EISBN: 978-1-62708-180-1
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006785
EISBN: 978-1-62708-295-2
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006813
EISBN: 978-1-62708-329-4
..., and ammonia can be very corrosive environments. Another cause of inadvertent general corrosion is improper chemical cleaning using uninhibited acids, excessive temperatures, or prolonged contact time. Water used to wash fire-side deposits where high-sulfur fuel oil or gas was fired will also create very...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006819
EISBN: 978-1-62708-329-4
... . A noteworthy pressure vessel failure in 2006 at a polyethylene-wax-processing facility in Houston, Texas, resulted in an explosion and a subsequent fire, ultimately injuring local residents and firefighters ( Ref 21 ). Mechanical fatigue damage from pressure cycling, coupled with a poor-quality pressure...