Skip Nav Destination
Close Modal
By
K.K. Vasu
Search Results for
Fe-0.10C
Update search
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
NARROW
Format
Topics
Book Series
Date
Availability
1-1 of 1
Search Results for Fe-0.10C
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Book Chapter
Failure of a Reversible Flap Valve in a Thermal Power Station
Available to PurchaseSeries: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001353
EISBN: 978-1-62708-215-0
... in low toughness. It was recommended that fully killed carbon steel with a fine-grain microstructure be used. Redesign of the flap to remove the step in the forging that acted as a notch was also recommended. Electric power generation Forgings Marine environments Weldments Fe-0.10C Fe-0.19C...
Abstract
A reversible four-way carbon steel flap valve in a thermal power station failed after 7 years of service. The flap had been fabricated by welding two carbon steel plates to both sides of a carbon steel forging. The valve was used for reversing the flow direction of seawater in the cooling system of a condenser. Visual examination of the flap showed crystalline fracture, indicating a brittle failure. Metallographic examination, chemical analyses, and tensile and impact testing indicated that the failure was caused by the notch sensitivity of the forging material, which resulted in low toughness. It was recommended that fully killed carbon steel with a fine-grain microstructure be used. Redesign of the flap to remove the step in the forging that acted as a notch was also recommended.