1-20 of 241 Search Results for

Drying

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Image
Published: 01 December 1992
Fig. 1 Cross section of traveling grate furnace. UDD, updraft drying; DDD, down draft drying; PH, preheating; F, firing; AF, after firing; C, cooling. More
Image
Published: 01 June 2019
Fig. 7 Dependence of babbit wear intensity on β-phase grain size at dry sliding More
Image
Published: 01 June 2019
Fig. 1 Dry tubercle and ring stains on pipe weld in the melter cooling water system. More
Image
Published: 01 June 2019
Fig. 1 Documentation of dry MT powder inspection results for vaporizer coil 6. More
Image
Published: 15 January 2021
Fig. 1 (a) Appearance of a steel surface after dry sliding against a softer Cu-8%Sn alloy. Adhesive wear of the bronze is evidenced by the transfer of many bronze particles onto the steel surface. Reprinted from Ref 11 with permission from Elsevier. (b) Adhesive wear of Ti-6Al-4V after dry More
Image
Published: 15 January 2021
Fig. 6 Dry sliding wear maps. (a) Steels. Source: Ref 5 , 17 . (b) 7071 aluminum alloy sliding against AISI 32100 steel. Source: Ref 18 . (c) Low-metallic-friction material sliding against pearlitic cast iron. Source: Ref 19 More
Image
Published: 01 December 1992
Fig. 3 SEM fractograph of specimen bend tested at 50% load in dry air; time to failure, 24 days. Large arrow indicates area of maximum tensile stress. The segment is from the uranium side of the specimen. Most of the surface displays ductile silver/silver fracture. A few islands of uranium More
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.auto.c0090451
EISBN: 978-1-62708-218-1
... to alternating temperatures of -40 and 180 deg C (-40 and 360 deg F)). Prior to molding, the resin had reportedly been dried at 135 deg C (275 deg F). The drying process usually lasted 6 h, but occasionally, the material was dried overnight. Comparison investigation (visual inspection, 20x SEM views, micro-FTIR...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.petrol.c0048698
EISBN: 978-1-62708-228-0
... Abstract Wet natural gas was dried by being passed through a carbon steel vessel that contained a molecular-sieve drying agent. The drying agent became saturated after several hours in service and was regenerated by a gas that was heated to 290 to 345 deg C in a salt-bath heat exchanger...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.petrol.c0051866
EISBN: 978-1-62708-228-0
... fluids or modifying the fluids in the tubing or purging by flowing dry nitrogen to dry it out. Coiled steel Drilling Pitting (corrosion) Tubes Structural steel tubing Corrosion fatigue Coiled tubing is used in drilling operations because it eliminates the need for a drilling rig...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.pulp.c0091622
EISBN: 978-1-62708-230-3
...-SCC in an area of debris buildup. It appeared the original casting suffered SCC in a low-oxygen area high in chlorides from repeated wet/dry cycles where there was a buildup of debris. Recommendations included redesigning the neck liner to eliminate the abrupt change where there was debris buildup...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.pulp.c0089567
EISBN: 978-1-62708-230-3
... Abstract A paper drier head manufactured from gray cast iron was removed from service as a result of NDE detection of crack-like surface discontinuities. This component was subjected to internal steam pressure to provide heat energy for drying. Investigation (visual inspection, chemical...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.homegoods.c9001627
EISBN: 978-1-62708-222-8
.... Based on these findings, one of the recommendations was to use thicker pads between the sinks to allow any such liquids to dry before causing corrosion damage. Chemical analysis Chlorides Discoloration Kitchen sinks 304 UNS S30400 (Other, miscellaneous, or unspecified) failure A section...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.homegoods.c0090424
EISBN: 978-1-62708-222-8
... is a common breakdown product produced during the decomposition of polycarbonate. The conclusion was that the most likely cause of the molecular degradation was improper drying and/or exposure to excessive heat during the injection molding process that in turn caused the material degradation. Brackets...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001676
EISBN: 978-1-62708-229-7
... the interaction with gamma radiation) and to prevent corrosion. A number of failures have occurred over the years because of a loss of the He cover gas in the assembly. This has resulted in either acid attack on the Inconel 600 sheath in a wet environment or gaseous corrosion in a dry environment. In the latter...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.petrol.c9001235
EISBN: 978-1-62708-228-0
... may be considered. One is to desulfurize the gas. Based on tests, however, the desulfurization would have to be carried very far to be successful. The second possibility is to dry the gas to such an extent as to prevent condensate, and this corrosion, from forming no matter how low winter temperatures...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.design.c9001423
EISBN: 978-1-62708-233-4
... Abstract Five cylinders out of a group of nine in a drying machine developed leaks after a few months service in a textile mill. Leakage was reported from locations between the hoop and body and from the circumferential welds. The materials in the affected area were 18/8 Ti and 18/10/3/Mo...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.modes.c0046512
EISBN: 978-1-62708-234-1
... the actuators using dry vellum gaskets. Actuators Molybdenum disulfide Solid lubricants Spacers Aluminum Galvanic corrosion Immediately after installation, leakage was observed at the mounting surface ( Fig. 1a ) of several rebuilt hydraulic actuators that had been in storage for up to three...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.auto.c0091598
EISBN: 978-1-62708-218-1
... concentrated ammonium nitrate solution. Recommendations included the cost-effective solution of applying a three-coat epoxy-type coating with a total dry thickness of 0.3 mm (0.013 in.) to the interior surfaces of the hoppers. Ammonium nitrate Epoxy Hoppers ASTM A611 ASTM A570 Intergranular fracture...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.auto.c0048586
EISBN: 978-1-62708-218-1
... of a recurrence, the wheel nuts were tightened with an air impact wrench to a torque of 610 to 678 J (450 to 500 ft · lb) dry. All wheel studs were checked at normal maintenance periods to ensure uniform and proper loading, and no further failures occurred. Bending fatigue Studs 4520 UNS G45200 Fatigue...