Published: 01 December 1992
Fig. 3 Results of dimensional measurements along a transverse section of the endcap through the center of the failed spot weld. Downward permanent deflection of the endcap outer skin on both sides of the bracket is evident. Dimensions given in inches. More
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c9001905
EISBN: 978-1-62708-217-4
... confirmed that the component was in the annealed condition and not in the required work-hardened 1/4-hard condition. Bombs (weapons) Retaining bands Equiaxed structure Dimensional measurements 302 UNS S30200 Heat treating related failures Introduction Component: MK#15/Mod 6 Snakeye bomb...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c0048299
EISBN: 978-1-62708-229-7
... . Investigation Visual examination showed that all of the ruptures were similar. Figure 1(b) illustrates one of these narrow fissure-type failures. Dimensional measurements showed no swelling except at the failure. Wall thickness away from the rupture was 3.8 to 3.9 mm (0.148 to 0.154 in.), depending...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c9001600
EISBN: 978-1-62708-217-4
..., residual stress, and TEM analysis. Dimensional Verification The thickness of the web at the fatigue crack initiation site was measured and compared for each of the four components. As shown in Table 1 , a trend was noted. The thickness measurements of the IT webs were appreciably lower than those...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.usage.c0048303
EISBN: 978-1-62708-236-5
.... Etched with nital. 500× Investigation Chemical analysis of the tube sample for chromium and molybdenum revealed: Element Sample, % SA-213, grade T-22 specification, % Cr 2.35 1.90–2.60 Mo 0.91 0.87–1.13 This confirmed the material as T-22. Dimensional measurements...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001312
EISBN: 978-1-62708-215-0
... in.) Fig. 3 Dimensional profiles of the dashpot before (left) and after failure. Dimensions given in millimetres. *Portions blown off during the accident. **Measurements of the flattened tubular portion Fig. 5 SEM micrographs of the fracture surfaces. (a) Upper and lower circumferential surface...
Series: ASM Failure Analysis Case Histories
Volume: 1
Publisher: ASM International
Published: 01 December 1992
DOI: 10.31399/asm.fach.v01.c9001028
EISBN: 978-1-62708-214-3
... weld. (b) Inside, showing upper portion of the internal bracket. Fig. 3 Results of dimensional measurements along a transverse section of the endcap through the center of the failed spot weld. Downward permanent deflection of the endcap outer skin on both sides of the bracket is evident...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.bldgs.c9001697
EISBN: 978-1-62708-219-8
... was determined to be Type M ( Tables 1 and 2 ). Type M copper was specified for above ground applications, but was not the specified material for below ground use. The material was therefore not in conformance with the project's design specifications. Results of dimensional measurements of the pipes...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.aero.c9001583
EISBN: 978-1-62708-217-4
... Abstract The purpose of this investigation was to determine the root cause of the differences noted in the fatigue test data of main rotor spindle assembly retaining rods fabricated from three different vendors, as part of a Second Source evaluation process. ARL performed dimensional...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c9001580
EISBN: 978-1-62708-229-7
... surfaces, thus there was concern that the reflectivity of the shiny stainless steel canister surface could increase the variability in the measurements. The LDS was taken to a Coherent Optical Measurements Lab to quantify the error caused by can surface reflectivity. A three-dimensional micrometer...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001298
EISBN: 978-1-62708-215-0
... corrosion pit, 0.38 mm (0.015 in.) deep, led to a fatigue failure of the spar The failure initiated on the pylon side of the blade. Dimensional analysis of the spar near the failure revealed measurements within engineering drawing tolerances. Though corrosion pitting was present, there was an absence...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001334
EISBN: 978-1-62708-215-0
..., an irregularly shaped hole approximately 3 mm (0.12 in.) in diameter and two smaller holes were observed. The outer surface (steam side) of the tube appeared to be uniformly black. The inner surface exhibited a uniform brown corrosion product. There was no indication of preferential deposition. Dimensional...
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001340
EISBN: 978-1-62708-215-0
...) and an outlet temperature of 193 °C (380 °F). The boiler tubes were specified as 6.35-cm (2.5-in.) outer diameter carbon steel tubing with 0.368-cm (0.145-in.) wall thickness. The exact grade of the steel was not reported. To evaluate the damage to the boiler tubes, dimensional measurements were taken...
Image
Published: 01 December 1993
Fig. 3 Dimensional profiles of the dashpot before (left) and after failure. Dimensions given in millimetres. *Portions blown off during the accident. **Measurements of the flattened tubular portion More
Series: ASM Failure Analysis Case Histories
Volume: 2
Publisher: ASM International
Published: 01 December 1993
DOI: 10.31399/asm.fach.v02.c9001315
EISBN: 978-1-62708-215-0
... Fig. 1 Dimensional details of the AM350 bellows. Dimensions are given in millimeters. Dimensional details of the AM350 bellows. Dimensions are given in millimeters. Fig. 2 Optical micrographs showing weld profiles and extent of fusion Fig. 3 Optical micrograph showing...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003536
EISBN: 978-1-62708-180-1
... that are based on fracture profilometry. This is followed by a section describing the methods based on scanning electron microscope fractography. The article also addresses procedures for three-dimensional fracture surface reconstruction. In each case, sufficient methodological details, governing equations...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006772
EISBN: 978-1-62708-295-2
... in a digital format similar to a point cloud not only allows for virtual examination of the scene but also provides dimensional information. Accuracy of the measurements obtained from a point cloud are dependent on the technology deployed (sUAS or laser scanner) and the level of computational success...
Series: ASM Handbook
Volume: 11A
Publisher: ASM International
Published: 30 August 2021
DOI: 10.31399/asm.hb.v11A.a0006801
EISBN: 978-1-62708-329-4
... manner, quantity, and distribution used in production. Grid strain analysis has greater opportunities for measurement error. The grid template/stencil has a 2% maximum error in the dimensions. The polyester film scale has dimensional errors, and lighting/parallax can influence the reading...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.power.c0048845
EISBN: 978-1-62708-229-7
... welds in the secondary superheater outlet headers (constructed of SA335-P11 material) of a major boiler were described as an example. The OD of the header was measured to detect the amount of swelling and found to have increased 1.6% since its installation. Ligament cracks extending from tube seat...
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006764
EISBN: 978-1-62708-295-2
... Laser/dimensional metrology photogrammetry, laser total station, laser tracker, coordinate measurement machines Either angle/angle stereo image or angle/time-of-flight allows measurement of surface profile of the object. Reverse engineering, dimensional metrology, crack and pit detection Limited...