1-9 of 9 Search Results for

Autoclaves

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.steel.c9001668
EISBN: 978-1-62708-232-7
... Abstract A detailed investigative failure analysis was conducted on an autoclave which blew apart in a furnace for no apparent reason. Bolt failure resulted in separation of the autoclave lid and subsequent destruction of the furnace. Analysis using metallography, fractography, mechanical...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.chem.c9001181
EISBN: 978-1-62708-220-4
... from a material immune to stress-corrosion cracking or to use interchangeable linings of such a material. A nickel alloy could be considered. Autoclaves Explosions Pressure vessels X8CrNiMoVNb 16 13 K Transgranular fracture Stress-corrosion cracking The damaged forged pressure vessel...
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.chem.c9001437
EISBN: 978-1-62708-220-4
... Abstract A steam jacketed autoclave of orthodox design was fabricated from mild steel for a working pressure of 320 psi. The only unusual feature in its construction was a protective layer of weld metal, which was deposited on the internal surface of the upper half of the 1 in. thick shell...
Image
Published: 01 June 2019
Fig. 1 Autoclave system schematic. More
Image
Published: 01 June 2019
Fig. 2 Consequence of autoclave failure. More
Series: ASM Failure Analysis Case Histories
Volume: 3
Publisher: ASM International
Published: 01 December 2019
DOI: 10.31399/asm.fach.v03.c9001769
EISBN: 978-1-62708-241-9
... followed by gentle cleaning with trichloroethylene. These coupons were autoclaved at 121 °C at 15 psi for 15 min. The autoclaved coupons were immersed in calcium precipitating bacterial culture system described above over a period of 2–3 weeks for the formation of biofilm. The coupons were removed from...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003500
EISBN: 978-1-62708-180-1
Series: ASM Handbook
Volume: 11
Publisher: ASM International
Published: 15 January 2021
DOI: 10.31399/asm.hb.v11.a0006753
EISBN: 978-1-62708-295-2
... attack or hydrogen embrittlement due to acid cleaning Hydrogen embrittlement due to plating Stress corrosion from caustic autoclave core leaching of castings Assembly at factory/installation at site Misalignment Missing/wrong parts Improper fit-up Inappropriate fastening system...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0003553
EISBN: 978-1-62708-180-1