1-2 of 2 Search Results for

ASTM A201 Grade B

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Series: ASM Failure Analysis Case Histories
Publisher: ASM International
Published: 01 June 2019
DOI: 10.31399/asm.fach.chem.c0048840
EISBN: 978-1-62708-220-4
...Abstract Abstract A spherical carbon steel fixed-catalyst bed reactor, fabricated from French steel A42C-3S, approximately equivalent to ASTM A201 grade B, failed after 20 years of service while in a standby condition. The unit was found to contain primarily hydrogen at the time of failure...
Series: ASM Handbook Archive
Volume: 11
Publisher: ASM International
Published: 01 January 2002
DOI: 10.31399/asm.hb.v11.a0001818
EISBN: 978-1-62708-180-1
.... Example 2: Rupture of a Ferritic Steel Return Bend Because of Inclusions After 2 years of service, a return bend from a triolefin-unit heater ruptured ( Fig. 3a ). The bend was made from 115-mm (4 1 2 -in.) schedule 40 (6.0 mm, or 0.237-in., wall thickness) pipe of ASTM A213, grade T11...