Use of Electron Fractography to Diagnose Hairline Cracking in an AISI 4340 Main Landing Gear Cylinder Available to Purchase
Group Leader
-
Published:2019
Abstract
Ground maintenance personnel discovered hydraulic fluid leaking from two small cracks in a main landing gear cylinder made from AISI 4340 Cr-Mo-Ni alloy steel. Failure of the part had initiated on the ID of the cylinder. Numerous cracks were found under the chromium plate. A 6500x electron fractograph showed cracking was predominantly intergranular with hairline indications. Leaking had occurred only 43 h after overhaul of the part. Total service time on the part was 9488 h. It was concluded that cracking on the ID was caused by hydrogen embrittlement which occurred during or after overhaul. The specific source of hydrogen which produced failure was not ascertainable.
James A. Scott, Use of Electron Fractography to Diagnose Hairline Cracking in an AISI 4340 Main Landing Gear Cylinder, ASM Failure Analysis Case Histories: Air and Spacecraft, ASM International, 2019, https://doi.org/10.31399/asm.fach.aero.c9001540