ASM Failure Analysis Case Histories: Automobiles and Trucks
Catastrophic Failure of a Fan in a Diesel Engine Cooler
-
Published:2019
Abstract
The fan used to cool a diesel engine fractured catastrophically after approximately 100 h of operation. The fan failed at a spider, which was resistance spot welded to a shim placed between two circular spiders of 3 mm thickness. The detailed analysis of the fracture indicated that the premature failure of the fan was due to inadequate bonding between the sheets at the weld nugget. The fracture was initiated from the nugget-plate interface. The inadequate penetration and lack of fusion between the steel sheets during resistance spot welding led to poor weld strength and the fracture during operation. The...
Sign in
ASM members
Member Sign InB.V. Krishna, R.K. Sidhu, Catastrophic Failure of a Fan in a Diesel Engine Cooler, ASM Failure Analysis Case Histories: Automobiles and Trucks, ASM International, 2019, https://doi.org/10.31399/asm.fach.auto.c9001612