Skip to Main Content

Abstract

Forged austenitic steel rings used on rotor shafts in two 100,000 kW generators burst from overstressing in a region of ventilation holes. A variety of causes contributed to the brittle fractures in the ductile austenitic alloy, including stress concentration by holes, work hardened metal in the bores, and a variable pattern of residual stress.

You do not currently have access to this chapter.
Don't already have an account? Register

2019. "Failures of Forged End Bells on Large Electric Generators", ASM Failure Analysis Case Histories: Failure Modes and Mechanisms