Skip to Main Content

Abstract

A 5000-gal (20,000-L) hot-water holding tank fractured at a large automotive manufacturing plant. The tank was made from Type 304 austenitic stainless steel. The inner diameter of the tank displayed a macroscopic, web-like network of cracks that deceptively suggested intergranular stress-corrosion cracking. The problem, however, originated on the outside surface of the tank where a tensile stress (due to low applied stress and fabrication-induced residual stresses) accelerated the growth of numerous stress corrosion cracks that eventually broke through to the inner surface, causing leakage and ultimately failure.

You do not currently have access to this chapter.
Don't already have an account? Register

Ronald J. Parrington, 2019. "Failure of a Stainless Steel Holding Tank", ASM Failure Analysis Case Histories: Buildings, Bridges, and Infrastructure