Two type 420 martensitic stainless steel load cell bodies, which had been installed under two of the four legs of a milk storage tank failed in service. The failure occurred near a change in section and involved fracture of the entire cross section. Examination showed a brittle fracture that was preceded by a small fatigue region. Pitting corrosion was evident at the fracture origin. The areas around the load cells had been subjected to regular washdowns using high-pressure hot water, and the pitting was attributed to crevice corrosion between the load cell and the holddown bolts. Prevention of such corrosion by the use of a flexible sealant to eliminate the crevice was recommended.

You do not currently have access to this chapter.
Don't already have an account? Register

Daryl C. Collins, 1993. "Corrosion Fatigue Failure of Stainless Steel Load Cells in a Milk Storage Tank", Handbook of Case Histories in Failure Analysis, Khlefa A. Esaklul