Two AISI type 316 stainless steel dished ends failed through the formation of intergranular stress-corrosion cracks (IGSCC) within a few months of service. The dished ends failed in the straight portions near the circumferential welds that joined the ends to the cylindrical portions of the vessel. Both dished ends were manufactured from the same batch and were supplied by the same manufacturer One of the dished ends had been exposed to sodium at 550 deg C (1020 deg F) for 500 h before failure due to sodium leakage was detected. The other dished end was used to fabricate a...