EDFA Technical Articles (2011) 13 (3): 18–26.
Published: 01 August 2011
...Cheryl Hartfield; Matt Hammer; Gonzalo Amador; Tom Moore This article discusses the practice of FIB-based in situ lift-out, a sample preparation method that has proven particularly useful for failure analysis. It explains how samples are now being made for a wide range of TEM techniques, including...
Journal Articles
EDFA Technical Articles (2018) 20 (2): 26–32.
Published: 01 May 2018
...Lucille A. Giannuzzi Ex-situ lift out (EXLO) techniques rely on van der Waals forces to transfer FIB milled specimens to various types of carriers using a glass probe micromanipulator. This article describes some of the latest EXLO techniques for site specific scanning transmission electron...
Journal Articles
EDFA Technical Articles (2023) 25 (1): 20–27.
Published: 01 February 2023
... ASM International FIB lift-out in situ lift-out Omniprobe TEM sample preparation ELECTRONIC DEVICE FAILURE ANALYSIS | VOLUME 25 NO. 1 2 0 httpsdoi.org/10.31399/asm.edfa.2023-1.p020 EDFAAO (2023) 1:20-27 1537-0755/$19.00 ©ASM International® INVENTOR'S CORNER TRANSFORMING AN INDUSTRY...
Journal Articles
EDFA Technical Articles (2014) 16 (1): 31–48.
Published: 01 February 2014
... about TEM/STEM sample preparation with state-of-the-art SEM/FIB systems and in situ lift-out techniques. He discussed the necessity of low-kilovolt cleaning for TEM sample quality. Other critical aspects covered by Brandon were minimizing curtaining, the importance of the protective covering material...
Journal Articles
EDFA Technical Articles (2013) 15 (1): 37–40.
Published: 01 February 2013
... for the increasingly stringent circuit edit and failure analysis requirements of WLP. EXpressLO for Routine Backside Milling Lucille A. Giannuzzi, L.A. Giannuzzi & Associates LLC [email protected] A new method and grid design was described for implementation of ex situ lift-out of FIB-prepared specimens...
Journal Articles
EDFA Technical Articles (2023) 25 (1): 4–8.
Published: 01 February 2023
.... This article will focus on FIB sample preparation, as it is a standardized process, to the point of automation, and therefore presents the most direct route to routine in situ TEM characterization within existing workflows. FIB-prepared TEM samples are typically mounted to TEM lift-out grids, or semicircular...
Journal Articles
EDFA Technical Articles (2019) 21 (4): 4–12.
Published: 01 November 2019
... for Ex-situ Lift-Out TEM Sample Preparation with FIB for 14 nm FinFET, Proc Int. Symp. Test. Fail. Anal. (ISTFA), 2014, p. 478-482. 7. J. Mayer, L.A. Giannuzzi, T. Kamino, and J. Michael: TEM Sample Preparation and FIB-Induced Damage, MRS Bulletin, 2007, 32, p. 400-407. 8. L.A. Giannuzzi and F.A...
Journal Articles
EDFA Technical Articles (2013) 15 (3): 12–19.
Published: 01 August 2013
.... The solutions developed to successfully address these challenges are described here, which also opened up new areas of FIB-SEM applications. Nanomanipulation An established technique for lifting out a TEM la- Fig. 1 Nanocrystal of InN grown with six facets on one end and twelve on the other, tapered...
Journal Articles
EDFA Technical Articles (2024) 26 (4): 20–26.
Published: 01 November 2024
.... REFERENCES 1. J. Zhu, et al.: Tri-Directional TEM Failure Analysis on Sample Prepared by In-Situ Lift-Out FIB and Flipstage, Proc. Int. Symp.Test. Fail. Anal. (ISTFA), 2014, doi.org/10.31399/asm.cp.istfa2014p0480. 2. T. Meyer, et al.: Site-specific Plan-view TEM Lamella Preparation of Pristine Surfaces...
Journal Articles
EDFA Technical Articles (2013) 15 (4): 4–11.
Published: 01 November 2013
... is to lift out only a small portion, including the ROI (~2 × 2 × 2 µm3), from the donor material and place it on top of such a silicon post. Thus, only a small top portion needs to be sharpened, which increases the throughput. This site-specific lift-out approach was first presented in detail in Ref 7...
Journal Articles
EDFA Technical Articles (2014) 16 (4): 4–12.
Published: 01 November 2014
... out of the lab and traveled to the failure site, where tests could be made in situ. Importantly, failing modules could be fixed in place with epoxy. This step of fixing the position of a module with reference to a connector allowed a failing module and socket to be cross sectioned simultaneously...
Journal Articles
EDFA Technical Articles (2022) 24 (2): 18–23.
Published: 01 May 2022
... targeting the specific device of interest. The process then begins with normal TEM inverted-preparation methods where an in-situ lift out is performed. The sample is then flipped 180 degrees, such that the gallium-ion beam now mills from the underside of the device. This method minimizes the curtaining...
Journal Articles
EDFA Technical Articles (2014) 16 (1): 18–23.
Published: 01 February 2014
... of IBM. Oliver Progress towards Cryo FIB Lift-Out was Sir Charles Oatley s second Ph.D. student at Cheryl Hartfield* and Nicholas Antoniou** Cambridge University to work on the SEM (after *Oxford Instruments; **Harvard University Dennis McMullan) and is considered to be one of the founding fathers...
Journal Articles
EDFA Technical Articles (2021) 23 (2): 22–32.
Published: 01 May 2021
... (FIB) milling and standard in-situ lift-out in a Zeiss CrossBeam 1540XB FIB-scanning electron microscope (SEM). A probe of 10 pA beam current at 30 kV acceleration voltage was used for the final polishing. All edfas.org 23 ELECTRONIC DEVICE FAILURE ANALYSIS | VOLUME 23 NO. 2 TEM work was performed...
Journal Articles
EDFA Technical Articles (2020) 22 (4): 4–8.
Published: 01 November 2020
.... 2015, doi: 10.1021/acs.nanolett.5b00901. 7. M. Mecklenburg, et al.: Fabrication of a Lift-Out Grid with Electrical Contacts for Focused Ion Beam Preparation of Lamella for In Situ Transmission Electron Microscopy, Microsc. Microanal., 19(S2), Aug. 2013, p. 458 459, doi: 10.1017/S1431927613004285. 8...
Journal Articles
EDFA Technical Articles (2017) 19 (1): 26–40.
Published: 01 February 2017
... separated from the surface by a thin layer of polymer prior to the FIB lamella preparation. The next two presentations dealt with advanced TEM preparation methods. Stephan Kleindiek of Kleindiek Nanotechnik presented A Novel Software Approach to TEM Sample Lift-Out Using the Lift-Out Shuttle. Richard...
Journal Articles
EDFA Technical Articles (2023) 25 (1): 9–13.
Published: 01 February 2023
... Probe interface module to attach the probe to the AFM Microwave electronics ScanWave has been designed to work on major AFM platforms and is compatible with many AFM scanning modes such as contact mode, tapping mode, and lift mode. Since sMIM is a near-field measurement, resolution below the tip...
Journal Articles
EDFA Technical Articles (2024) 26 (1): 14–21.
Published: 01 February 2024
.... voltage, for example, to a 100 nm diameter (or less) needle-shaped specimen. To prepare APT specimens with such geometry, a focused ion beam (FIB) lift-out method is often used.[10] Figure 2 shows an example of APT tip preparation from a bulk substrate using this approach. First, the area of interest...
Journal Articles
EDFA Technical Articles (2013) 15 (2): 4–13.
Published: 01 May 2013
...- Stained/deformed contacts, Pregnant capacitors that outlines which circumstances the protection structures sockets, plugs failure has generated in which cir- Dielectric breakdown Molten/lifted wirebonds Damaged discrete diodes cuitry. This also includes whether its appearance was a one-time exception...
Journal Articles
EDFA Technical Articles (2021) 23 (4): 28–37.
Published: 01 November 2021
... to edfas.org excite the ion out of the desired state or to reorder ions in a chain (logical qubit) and scramble any encoded information. Thus, the desired vacuum pressure is the lowest possible, typically around 10 12 Torr, near-XHV (extreme high vacuum). These ultra-low pressures are realized by (a) 29 baking...