Skip Nav Destination
Close Modal
Search Results for
reheater tubes
Update search
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
Filter
- Title
- Authors
- Author Affiliations
- Full Text
- Abstract
- Keywords
- DOI
- ISBN
- EISBN
- Issue
- ISSN
- EISSN
- Volume
- References
NARROW
Format
Topics
Subjects
Article Type
Volume Subject Area
Date
Availability
1-20 of 159
Search Results for reheater tubes
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
1
Sort by
Proceedings Papers
AM-EPRI2019, 2019 Joint EPRI – 123HiMAT International Conference on Advances in High-Temperature Materials, 685-693, October 21–24, 2019,
... Abstract The fall-off of oxide scale with poor adhesion inside superheater/reheater tubes in boilers for (ultra) supercritical power unit is the main cause of accidents such as superheater/reheater blockage, tube explosion and solid particle erosion in the steam turbine which cause serious...
Abstract
View Papertitled, Study on the Test Method of Oxide Scale Adhesion inside Superheater/<span class="search-highlight">Reheater</span> <span class="search-highlight">Tubes</span> Based on Image Recognition
View
PDF
for content titled, Study on the Test Method of Oxide Scale Adhesion inside Superheater/<span class="search-highlight">Reheater</span> <span class="search-highlight">Tubes</span> Based on Image Recognition
The fall-off of oxide scale with poor adhesion inside superheater/reheater tubes in boilers for (ultra) supercritical power unit is the main cause of accidents such as superheater/reheater blockage, tube explosion and solid particle erosion in the steam turbine which cause serious economic losses. However, there is still no method for testing and assessing the adhesion of oxide scale inside the tube. A method for testing the adhesion of corrosion products in tubes by spiral lines is proposed in this paper, and the accuracy of adhesion evaluation is improved by adopting the image recognition method.
Proceedings Papers
AM-EPRI2019, 2019 Joint EPRI – 123HiMAT International Conference on Advances in High-Temperature Materials, 1014-1023, October 21–24, 2019,
... Abstract The combustion of coal and biomass fuels in power plants generates deposits on the surfaces of superheater / reheater tubes that can lead to fireside corrosion. This type of materials degradation can limit the lives of such tubes in the long term, and better methods are needed...
Abstract
View Papertitled, Approaches to Modeling Fireside Corrosion of Superheater/<span class="search-highlight">Reheater</span> <span class="search-highlight">Tubes</span> in Coal and Biomass Fired Combustion Power Plants
View
PDF
for content titled, Approaches to Modeling Fireside Corrosion of Superheater/<span class="search-highlight">Reheater</span> <span class="search-highlight">Tubes</span> in Coal and Biomass Fired Combustion Power Plants
The combustion of coal and biomass fuels in power plants generates deposits on the surfaces of superheater / reheater tubes that can lead to fireside corrosion. This type of materials degradation can limit the lives of such tubes in the long term, and better methods are needed to produce predictive models for such damage. This paper reports on four different approaches that are being investigated to tackle the challenge of modelling fireside corrosion damage on superheaters / reheaters: (a) CFD models to predict deposition onto tube surfaces; (b) generation of a database of available fireside corrosion data; (c) development of mechanistic and statistically based models of fireside corrosion from laboratory exposures and dimensional metrology; (d) statistical analysis of plant derived fireside corrosion datasets using multi-variable statistical techniques, such as Partial Least Squares Regression (PLSR). An improved understanding of the factors that influence fireside corrosion is resulting from the use of a combination of these different approaches to develop a suite of models for fireside corrosion damage.
Proceedings Papers
AM-EPRI2007, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Fifth International Conference, 320-337, October 3–5, 2007,
... Abstract Alloy 33 is a weld overlay material that has generated a lot of interest in the fossil boiler industry. The high chromium content of Alloy 33 has been shown to provide excellent corrosion protection in both waterwall and superheater/reheater tube applications. For waterwall...
Abstract
View Papertitled, Alloy 33: Update on Field Experience in Water Walls and Superheaters
View
PDF
for content titled, Alloy 33: Update on Field Experience in Water Walls and Superheaters
Alloy 33 is a weld overlay material that has generated a lot of interest in the fossil boiler industry. The high chromium content of Alloy 33 has been shown to provide excellent corrosion protection in both waterwall and superheater/reheater tube applications. For waterwall applications, the corrosion resistance has been demonstrated in both laboratory and field tests conducted over the last 5 years. In addition to corrosion resistance, the Alloy 33 has also shown that it is also resistant to cracking (although no material is 100% immune). In the superheater/reheater, the use of spiral clad weld overlay tubes is able to provide resistance to excellent coal ash corrosion. Laboratory and field tests have shown Alloy 33 to have among the best corrosion resistance of all materials studied. The application of Alloy 33 is also easier than other more highly alloyed materials (such as FM-72) and is less expensive. As a result of these favorable experiences, Alloy 33 is now being used commercially to weld overlay both waterwall and superheater/reheater tubes on fossil boilers.
Proceedings Papers
AM-EPRI2007, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Fifth International Conference, 185-196, October 3–5, 2007,
... strengths and microstructural integrity across the 600-800°C temperature range. These innovative steel tubes have been successfully installed in the Eddystone No. 3 USC power plant as superheater and reheater tubes since 1991, with subsequent microstructural investigations after long-term service exposure...
Abstract
View Papertitled, Long-Term Creep Properties and Microstructure of Super304H, TP347HFG and HR3C for Advanced USC Boilers
View
PDF
for content titled, Long-Term Creep Properties and Microstructure of Super304H, TP347HFG and HR3C for Advanced USC Boilers
SUPER304H (18Cr-9Ni-3Cu-Nb-N, ASME CC2328) and TP347HFG (18Cr-12Ni-Nb, ASME SA213) are advanced fine-grained microstructure steel tubes developed for high strength and superior steam oxidation resistance. Their exceptional performance is demonstrated by the longest creep rupture tests, with SUPER304H tested at 600°C for 85,426 hours and TP347HFG at 700°C for 55,858 hours, both maintaining stable strength and microstructure with minimal σ phase formation and absence of other brittle phases compared to conventional austenitic stainless steels. HR3C (25Cr-20Ni-Nb-N, ASME CC2115) was specifically developed for high-strength, high-corrosion-resistant steel tubes used in severe corrosion environments of ultra-supercritical (USC) boilers operating at steam temperatures around 600°C. The longest creep test for HR3C, conducted at 700°C and 69 MPa for 88,362 hours, confirmed its high and stable creep strengths and microstructural integrity across the 600-800°C temperature range. These innovative steel tubes have been successfully installed in the Eddystone No. 3 USC power plant as superheater and reheater tubes since 1991, with subsequent microstructural investigations after long-term service exposure revealing their remarkable performance. The paper provides an up-to-date analysis of the long-term creep rupture properties and microstructural changes of these steels following extended creep rupture and aging processes, highlighting their successful application as standard materials for superheater and reheater tubes in newly constructed ultra-supercritical boilers worldwide.
Proceedings Papers
AM-EPRI2019, 2019 Joint EPRI – 123HiMAT International Conference on Advances in High-Temperature Materials, 703-714, October 21–24, 2019,
... Abstract Advanced austenitic stainless steels, such as Super 304H, have been used in reheater and superheater tubes in supercritical and ultra-supercritical power plants for many years now. It is important to characterize the microstructure of ex-service reheater and superheater tubes...
Abstract
View Papertitled, Characterization of the Microstructural Evolution of Aged Super 304H (UNS S30432) Advanced Austenitic Stainless Steel
View
PDF
for content titled, Characterization of the Microstructural Evolution of Aged Super 304H (UNS S30432) Advanced Austenitic Stainless Steel
Advanced austenitic stainless steels, such as Super 304H, have been used in reheater and superheater tubes in supercritical and ultra-supercritical power plants for many years now. It is important to characterize the microstructure of ex-service reheater and superheater tubes as this will help researchers understand the long-term microstructural evolution and degradation of the material, which can impact the performance and lifetime of the components that are in service. In this research, the microstructure of an ex-service Super 304H reheater tube that has been in service for 99,000 hours at an approximate metal temperature of 873K (600°C) has been characterized. The characterization techniques used were electron microscopy-based and included imaging and chemical analysis techniques. Seven phases were observed as a result of the characterization work. The phases observed were MX carbonitrides rich in niobium, copper-rich particles, M 23 C 6 , sigma phase, Z phase, a cored phase, and a BCC phase.
Proceedings Papers
AM-EPRI2013, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Seventh International Conference, 1372-1387, October 22–25, 2013,
... Abstract The use of the bainitic creep strength enhanced ferritic steel T/P23 has increased over the last decade in a wide range of applications including headers, superheater and reheater tubing and in waterwall tubing. Many issues have been reported in weldments of this material...
Abstract
View Papertitled, Creep Crack Growth in T23 Weldments
View
PDF
for content titled, Creep Crack Growth in T23 Weldments
The use of the bainitic creep strength enhanced ferritic steel T/P23 has increased over the last decade in a wide range of applications including headers, superheater and reheater tubing and in waterwall tubing. Many issues have been reported in weldments of this material, such as hydrogen induced cracking, reheat cracking and stress corrosion cracking. In order to help characterize high temperature cracking phenomena, including reheat cracking, a limited number of laboratory creep crack growth tests are being conducted as part of an ongoing project. Tests were run on as-welded sections with the test specimen crack-tip located in select zones of the weldment. Test temperatures are intended to bookend the range of applications from a waterwall condition of ~482°C (900°F) to the superheat/reheat condition of 565°C (1050°F). This paper describes the results of some early testing at 482°C (900°F). The tests provided useful insight into the cracking susceptibility of the material at this temperature with respect to not only time-dependent cracking, but also fatigue crack growth and fracture toughness. The paper includes details of the test method and results, as well as findings from post-test metallographic examinations of the tested specimens.
Proceedings Papers
AM-EPRI2016, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Eighth International Conference, 283-294, October 11–14, 2016,
... Super304H. Now, the China 620°C USC project needs a new austenitic heat resisting steel with high stress-rupture strength and good corrosion/oxidation resistance to fulfill the superheater/reheater tube components application requirement. A new austenitic heat resisting steel SP2215 is based on 22Cr-15Ni...
Abstract
View Papertitled, Research and Development of a New Austenitic Heat-Resisting Steel SP2215 for 600-620°C USC Boiler Superheater/<span class="search-highlight">Reheater</span> Application
View
PDF
for content titled, Research and Development of a New Austenitic Heat-Resisting Steel SP2215 for 600-620°C USC Boiler Superheater/<span class="search-highlight">Reheater</span> Application
For raising thermal efficiency and decreasing CO 2 emission, China had constructed the first 600°C ultra-supercritical(USC) fossil power plant in 2006. Now more than a hundred 600°C, 1000MW USC electric power units have been put in service. Recently, China has also developed 620°C USC power units and some of them have been put in service already. Meanwhile, more than fifty 620°C USC boilers will be produced by various China boiler companies. The austenitic steels TP347H, Super304H and HR3C are routinely used for 600°C USC boilers. Among these steels, a big amount of Super304H has been used for boiler superheater/reheater components application. However, Super304H is characterized by good stress-rupture strength but poor corrosion/oxidation resistance. On the other side, HR3C is characterized by very good corrosion/oxidation resistance but lower stress-rupture strength than Super304H. Now, the China 620°C USC project needs a new austenitic heat resisting steel with high stress-rupture strength and good corrosion/oxidation resistance to fulfill the superheater/reheater tube components application requirement. A new austenitic heat resisting steel SP2215 is based on 22Cr-15Ni with certain amount of Cu and also Nb and N for multiphase precipitation (MX, Cu-rich phase, NbCrN) strengthening in Fe-Cr-Ni austenitic matrix and M 23 C 6 carbide precipitation at grain boundaries. This SP2215 new austenitic steel is characterized by high stress-rupture strength (650°C, 105h>130MPa) and good corrosion/oxidation resistance. SP2215 austenitic steel has been commercially produced in tube product form. This SP2215 new austenitic heat-resisting steel is recommended to be used as superheater/reheater components for 620°C USC boiler application.
Proceedings Papers
AM-EPRI2013, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Seventh International Conference, 513-524, October 22–25, 2013,
... Abstract The use of the bainitic class of creep strength enhanced ferritic steels T/P23 and T24 has increased over the last decade in a wide range of applications including replacement headers, superheater and reheater tubing and in waterwall tubing. Many issues have been reported in one...
Abstract
View Papertitled, Material Behavior of T23 and T24
View
PDF
for content titled, Material Behavior of T23 and T24
The use of the bainitic class of creep strength enhanced ferritic steels T/P23 and T24 has increased over the last decade in a wide range of applications including replacement headers, superheater and reheater tubing and in waterwall tubing. Many issues have been reported in one or both of these materials including hydrogen induced cracking, reheat cracking and stress corrosion cracking. To appropriately address these issues, work has been initiated that includes a literature review, development of a database of phase transformation temperatures, investigation of tempering behavior, and an analysis of the effect of phase transformation on residual stresses. Such information will be provided in the context of understanding why these two materials appear highly susceptible to these cracking mechanisms.
Proceedings Papers
AM-EPRI2016, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Eighth International Conference, 600-609, October 11–14, 2016,
... Abstract Through inner wall oxidation scale thickness measurement, sampling tests and installation of wall temperature measuring device in the boiler, the equivalent wall temperature and its distribution of secondary high temperature reheater tube were estimated and verified...
Abstract
View Papertitled, Life Diagnosis and Extension of a High Temperature Heating Surface
View
PDF
for content titled, Life Diagnosis and Extension of a High Temperature Heating Surface
Through inner wall oxidation scale thickness measurement, sampling tests and installation of wall temperature measuring device in the boiler, the equivalent wall temperature and its distribution of secondary high temperature reheater tube were estimated and verified, and the temperature field distribution of tube platen which is of single peak distribution in the direction vertical to tube platen and an apparent lower temperature distribution covered by the smoke shield at the side of boiler wall were both obtained. For the middlemost 10CrMo910, the wall temperature of individual tube was getting close to 600°C. Afterwards material state and residual creep life of tube platen were estimated and calculated. The results of estimate and calculation show that the tube platen in the middle is not suitable for further service due to its degraded material states and lower antioxidant ability. Thus with consideration of distribution characteristics of temperature field, parts of tube platens in the middle are proposed to be replaced with T91 tubes. Furthermore, to avoid onsite heat treatment, 10CrMo910 tube covered by the smoke shield in the boiler was reserved, and a small piece of 10CrMo910 tube was welded at the inlet and outlet ends respectively in the manufactory.
Proceedings Papers
AM-EPRI2013, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Seventh International Conference, 847-862, October 22–25, 2013,
... environments. Both FM 72 and 72M show promise in addressing challenges like circumferential cracking and corrosion fatigue in waterwall tubing overlays. Additionally, 72M’s superior wear resistance makes it ideal for replacing erosion shields in superheater and reheater tubing. Beyond improved protection...
Abstract
View Papertitled, Inconel Filler Metal 72M Provides Corrosion and Wear Resistance and Low “Delta T” Through Walls of <span class="search-highlight">Tubing</span> in Fossil-Fired Boilers
View
PDF
for content titled, Inconel Filler Metal 72M Provides Corrosion and Wear Resistance and Low “Delta T” Through Walls of <span class="search-highlight">Tubing</span> in Fossil-Fired Boilers
Inconel Filler Metal 72 (FM 72) and Incoclad 671/800H co-extruded tubing have been successfully used for over 20 years to protect boiler tubing from high-temperature degradation. A newer alloy, FM 72M, offers superior weldability and the lowest corrosion rate in simulated low NOx environments. Both FM 72 and 72M show promise in addressing challenges like circumferential cracking and corrosion fatigue in waterwall tubing overlays. Additionally, 72M’s superior wear resistance makes it ideal for replacing erosion shields in superheater and reheater tubing. Beyond improved protection, these alloys exhibit increased hardness and thermal conductivity over time, leading to reduced temperature difference across the tube wall and consequently, enhanced boiler efficiency and lower maintenance costs. This paper discusses the historical selection of optimal alloys for waterwall and upper boiler tubing overlays, analyzes past failure mechanisms, and highlights the key properties of successful choices like FM 72 and 72M.
Proceedings Papers
AM-EPRI2004, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Fourth International Conference, 291-302, October 25–28, 2004,
.... Matching welding consumables for the developed steel have also been developed. Thus, newly developed XA704 is a promising material for superheater and reheater tubes for the “600°C generation” of USC boilers. XA704 has already been used in six power plants in Japan. Currently, the steel is being...
Abstract
View Papertitled, Properties of a Newly Developed 18Cr-9NI-Nb-V-W-N-Low C Austenitic Boiler <span class="search-highlight">Tube</span>
View
PDF
for content titled, Properties of a Newly Developed 18Cr-9NI-Nb-V-W-N-Low C Austenitic Boiler <span class="search-highlight">Tube</span>
A new 18Cr-9Ni-Nb-V-W-N-low C austenitic boiler tube (XA704) has been developed. Conventional high-strength austenitic stainless steel boiler tubes usually have high susceptibility to intergranular corrosion because of their high carbon content, and require special care for heated sections such as weld joints. Generally, when the carbon content decreases, the intergranular corrosion resistance improves, while the creep strength reduces. However, the creep strength of the developed steel is very high despite lower carbon content in comparison to conventional austenitic boiler tubes. The high temperature strength and the intergranular corrosion resistance of the steel are superior to those of conventional 18Cr steels such as TP347H. This excellent creep strength of XA704 is mainly due to precipitation strengthening by CrVN, and solid solution strengthening by tungsten and nitrogen. Matching welding consumables for the developed steel have also been developed. Thus, newly developed XA704 is a promising material for superheater and reheater tubes for the “600°C generation” of USC boilers. XA704 has already been used in six power plants in Japan. Currently, the steel is being standardized in the ASME Code.
Proceedings Papers
AM-EPRI2010, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Sixth International Conference, 72-85, August 31–September 3, 2010,
... reheat pipe in A-USC plants, while Ni-Co based alloys such as Alloys 617 and 263 strengthened by a large amount of the y’ phase are found to be the high strength candidate materials for superheater and reheater tubes, although they are prone to relaxation cracking after welding and to grain boundary...
Abstract
View Papertitled, Advances in Materials Technology for A-USC Power Plant Boilers
View
PDF
for content titled, Advances in Materials Technology for A-USC Power Plant Boilers
Recent advances in materials technology for boilers materials in the advanced USC (A-USC) power plants have been reviewed based on the experiences from the strengthening and degradation of long term creep properties and the relevant microstructural evolution in the advanced high Cr ferritic steels. P122 and P92 type steels are considered to exhibit the long term creep strength degradation over 600°C, which is mainly due to the instability of the martensitic microstructure strengthened too much by MX carbonitrides. This can be modified by reducing the precipitation of VN nitride and by optimizing the Cr content of the steels. An Fe-Ni based alloy, HR6W strengthened by the Fe2W type Laves phase is found to be a marginal strength level material with good ductility at high temperatures over 700°C and to be used for a large diameter heavy wall thick piping such as main steam pipe and hot reheat pipe in A-USC plants, while Ni-Co based alloys such as Alloys 617 and 263 strengthened by a large amount of the y’ phase are found to be the high strength candidate materials for superheater and reheater tubes, although they are prone to relaxation cracking after welding and to grain boundary embrittlement during long term creep exposure. A new Ni based alloy, HR35 strengthened by a-Cr phase and other intermetallic phases has been proposed for piping application, which is specially designed for a good resistance to relaxation cracking as well as high strength and a good resistance to steam oxidation and fire-side corrosion at high temperatures over 700°C.
Proceedings Papers
A Newly Designed Nickel-Based Superalloy GH750 For 700°C Advanced Ultra-Supercritical Power Plants
Free
AM-EPRI2016, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Eighth International Conference, 190-201, October 11–14, 2016,
... Abstract A new nickel-based superalloy, designated as GH750, was developed to meet the requirements of high temperature creep strength and corrosion resistance for superheater/reheater tube application of A-USC power plants at temperatures above 750°C. This paper introduces the design...
Abstract
View Papertitled, A Newly Designed Nickel-Based Superalloy GH750 For 700°C Advanced Ultra-Supercritical Power Plants
View
PDF
for content titled, A Newly Designed Nickel-Based Superalloy GH750 For 700°C Advanced Ultra-Supercritical Power Plants
A new nickel-based superalloy, designated as GH750, was developed to meet the requirements of high temperature creep strength and corrosion resistance for superheater/reheater tube application of A-USC power plants at temperatures above 750°C. This paper introduces the design of chemical composition, the process performance of tube fabrication, microstructure and the properties of alloy GH750, including thermodynamic calculation, room temperature and high temperature tensile properties, stress rupture strength and thermal stability. The manufacturing performance of alloy GH750 is excellent and it is easy to forge, hot extrusion and cold rolling. The results of the property evaluation show that alloy GH750 exhibits high tensile strength and tensile ductility at room and high temperatures. The 760°C/100,000h creep rupture strength of this alloy is larger than 100MPa clearly. Microstructure observation indicates that the precipitates of GH750 consist of the precipitation strengthening phase γ’, carbides MC and M 23 C 6 and no harmful and brittle TCP phases were found in the specimens of GH750 after long term exposure at 700~850°C. It can be expected for this new nickel-based superalloy GH750 to be used as the candidate boiler tube materials of A-USC power plants in the future.
Proceedings Papers
AM-EPRI2013, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Seventh International Conference, 131-142, October 22–25, 2013,
... Abstract To achieve the necessary creep-rupture lifetimes at the temperatures and pressures associated with advanced ultrasupercritical (A-USC) steam conditions (100,000 h at 100 MPa and 760°C), precipitation-strengthened nickel-based alloys are required for the superheater and reheater tubing...
Abstract
View Papertitled, Creep-Rupture Behavior of Precipitation-Strengthened Ni-Based Alloys Under Advanced Ultrasupercritical Steam Conditions
View
PDF
for content titled, Creep-Rupture Behavior of Precipitation-Strengthened Ni-Based Alloys Under Advanced Ultrasupercritical Steam Conditions
To achieve the necessary creep-rupture lifetimes at the temperatures and pressures associated with advanced ultrasupercritical (A-USC) steam conditions (100,000 h at 100 MPa and 760°C), precipitation-strengthened nickel-based alloys are required for the superheater and reheater tubing in A-USC boilers. Two alloys were considered to have potential for this application: Inconel 740 and Haynes 282 alloy. In support of this application, creep-rupture testing of several heats of Inconel 740 was conducted over a range of temperatures and stresses to develop confidence in qualitatively predicting creep lifetimes under conditions relevant to A-USC steam conditions, with the longest rupture times exceeding 30,000 h. For comparison, the creep-rupture behavior of Haynes 282 alloy was mapped as a function of temperature and stress, but with a significantly smaller dataset. Only a small difference in creep-rupture results between Inconel 740 and Inconel 740H was found although the latter alloy showed significantly greater resistance to η phase formation during testing. Little effect of prior aging treatments (for setting the γ′ precipitate structure) on creep-rupture behavior was observed. Results from a modified power law analysis showed that, while both Inconel 740 and Haynes 282 are projected to meet the A-USC lifetime requirements, the latter offered the potential for better long-term creep resistance.
Proceedings Papers
AM-EPRI2013, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Seventh International Conference, 265-275, October 22–25, 2013,
... Abstract Inconel alloy 740H is designated for boiler sueprheater/reheater tubes and main steam/header pipes application of advanced ultra-supercritical (A-USC) power plant at operating temperatures above 750°C. Microstructure evolution and precipitates stability in the samples of alloy 740H...
Abstract
View Papertitled, Microstructure Evolution and Precipitates Stability in Inconel Alloy 740H during Creep
View
PDF
for content titled, Microstructure Evolution and Precipitates Stability in Inconel Alloy 740H during Creep
Inconel alloy 740H is designated for boiler sueprheater/reheater tubes and main steam/header pipes application of advanced ultra-supercritical (A-USC) power plant at operating temperatures above 750°C. Microstructure evolution and precipitates stability in the samples of alloy 740H after creep-rupture test at 750°C, 800°C and 850°C were characterized in this paper by scanning electron microscopy, transmission electron microscopy and chemical phase analysis in details. The phase compositions of alloy 740H were also calculated by thermodynamic calculation. The research results indicate that the microstructure of this alloy keeps good thermal stability during creep-rupture test at 750°C, 800°C and 850°C. The precipitates are MC, M 23 C 6 and γ′ during creep-rupture test. The temperature of creep test has an important effect on the growth rate of γ′ phase. No harmful and brittle σ phase was found and also no γ′ to η transformation happened during creep. Thermodynamic calculations reveal almost all the major phases and their stable temperatures, fractions and compositions in the alloy. The calculated results of phase compositions are consistent with the results of chemical phase analysis. In brief, except of coarsening of γ′, Inconel alloy 740H maintains the very good structure stability at temperatures between 750°C and 850°C.
Proceedings Papers
AM-EPRI2013, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Seventh International Conference, 903-913, October 22–25, 2013,
... as candidate materials for piping and superheater/reheater tubes in an A-USC boiler. Weldments of these alloys were manufactured by GTAW, after which long term creep rupture tests were conducted at 700°C, 750°C and 800°C. Weldments of HR6W, HR35 and Alloy617 showed similar creep strength as compared...
Abstract
View Papertitled, Evaluation of Creep Rupture Strength in Ni-Based Alloy Weldments for an Advanced USC Boiler
View
PDF
for content titled, Evaluation of Creep Rupture Strength in Ni-Based Alloy Weldments for an Advanced USC Boiler
A Japanese national project has been undertaken since Aug. 2008 with the objective of developing an advanced ultra-supercritical power plant (A-USC) with a steam temperature of 700°C. Fe-Ni and Ni-based alloys, namely HR6W, HR35, Alloy617, Alloy740, Alloy263 and Alloy141, were taken as candidate materials for piping and superheater/reheater tubes in an A-USC boiler. Weldments of these alloys were manufactured by GTAW, after which long term creep rupture tests were conducted at 700°C, 750°C and 800°C. Weldments of HR6W, HR35 and Alloy617 showed similar creep strength as compared with these base metals. Weldments of Alloy740 tended to fail in the HAZ, and it is considered that voids and cracks preferentially formed in the small precipitation zone along the grain boundary in the HAZ. The creep strength of Alloy263 in weldments exhibited the highest level among all the alloys, although HAZ failure occurred in the low stress test condition. A weld strength reduction factor will be needed to avoid HAZ failure in Alloy740 and Alloy263. Also, to prevent premature failure in weld metal, optimization of the chemical composition of weld filler materials will be required.
Proceedings Papers
AM-EPRI2004, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Fourth International Conference, 872-884, October 25–28, 2004,
... Abstract Tests show that Inconel Filler Metal 72 overlay and/or Incoclad alloys 671/800HT are two material solutions that will provide adequate corrosion and erosion protection for superheater and reheater tubes in low-NOx boilers. This paper gives an overview of the corrosion issues involved...
Abstract
View Papertitled, Materials for Corrosion and Erosion Protection in Low NOx Power Boiler Super Heater <span class="search-highlight">Tubes</span>
View
PDF
for content titled, Materials for Corrosion and Erosion Protection in Low NOx Power Boiler Super Heater <span class="search-highlight">Tubes</span>
Tests show that Inconel Filler Metal 72 overlay and/or Incoclad alloys 671/800HT are two material solutions that will provide adequate corrosion and erosion protection for superheater and reheater tubes in low-NOx boilers. This paper gives an overview of the corrosion issues involved in these applications and presents test data for these materials.
Proceedings Papers
AM-EPRI2007, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Fifth International Conference, 520-530, October 3–5, 2007,
... conditions at a competitive cost. There are several programs around the world developing new ferritic and austenitic steels for superheater and reheater tubes exposed to the advanced steam conditions. The new steels must possess properties better than current steels in terms of creep strength, steamside...
Abstract
View Papertitled, Steamside Oxidation Behavior of Experimental 9%Cr Steels
View
PDF
for content titled, Steamside Oxidation Behavior of Experimental 9%Cr Steels
Reducing emissions and increasing economic competitiveness require more efficient steam power plants that utilize fossil fuels. One of the major challenges in designing these plants is the availability of materials that can stand the supercritical and ultra-supercritical steam conditions at a competitive cost. There are several programs around the world developing new ferritic and austenitic steels for superheater and reheater tubes exposed to the advanced steam conditions. The new steels must possess properties better than current steels in terms of creep strength, steamside oxidation resistance, fireside corrosion resistance, and thermal fatigue resistance. This paper introduces a series of experimental 9%Cr steels containing Cu, Co, and Ti. Stability of the phases in the new steels is discussed and compared to the phases in the commercially available materials. The steels were tested under both the dry and moist conditions at 650°C for their cyclical oxidation resistance. Results of oxidation tests are presented. Under the moist conditions, the experimental steels exhibited significantly less mass gain compared to the commercial P91 steel. Microstructural characterization of the scale revealed different oxide compositions.
Proceedings Papers
AM-EPRI2004, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Fourth International Conference, 100-115, October 25–28, 2004,
... between efficiency gains and material costs. coal-fired boilers economic analysis reheater tubes superheater tubes httpsdoi.org/10.31399/asm.cp.am-epri-2004p0100 Copyright © 2005 ASM International® 100 101 Figure 1. PC Block Flow Diagram (Subcritical, Wet Limestone Forced Oxidation FGD) 102...
Abstract
View Papertitled, Economic Analysis of New Coal-Fired Generation Options
View
PDF
for content titled, Economic Analysis of New Coal-Fired Generation Options
Coal-fired power plants are experiencing a resurgence due to cheaper prices compared to natural gas. However, environmental concerns remain. New technologies aim to tackle these issues by capturing emissions and boosting efficiency. EPRI's economic analysis highlights the potential of ultrasupercritical boilers with advanced materials, which could reach a remarkable 48% efficiency. However, these cutting-edge boilers come at a higher cost due to the expensive materials needed to withstand extremely high steam temperatures (around 730-760°C). The challenge lies in finding the optimal balance between efficiency gains and material costs.
Proceedings Papers
AM-EPRI2010, Advances in Materials Technology for Fossil Power Plants: Proceedings from the Sixth International Conference, 30-52, August 31–September 3, 2010,
... for fossil power plant application. China had established first USC power plant with steam parameters of 650°C and 25 MPa in the year of 2006. Austenitic heat-resistant steel Super 304H is mainly used as boiler superheater and reheater material. Ni-Cr-Fe base superalloy GH2984 was used as tube material...
Abstract
View Papertitled, Results from Structural Stability Studies of Advanced Heat-Resistant Steels and Alloys for Fossil Power Plants in China
View
PDF
for content titled, Results from Structural Stability Studies of Advanced Heat-Resistant Steels and Alloys for Fossil Power Plants in China
This overview paper summarizes part of structure stability study results in China on advanced heat-resistant steels, nickel-iron and nickel base superalloys such as 12Cr2MoWVTiB(GY102) ferritic steel, Super 304H austenitic steel, GH2984, Nimonic 80A and INCONEL 740 superalloys for fossil power plant application. China had established first USC power plant with steam parameters of 650°C and 25 MPa in the year of 2006. Austenitic heat-resistant steel Super 304H is mainly used as boiler superheater and reheater material. Ni-Cr-Fe base superalloy GH2984 was used as tube material for marine power application. Ni-Cr-Co type INCONEL 740 has been studied in a joint project with Special Metals Corp., USA for European USC model power plant with the steam temperature of 700°C. Nimonic 80A has been used as several stage USC steam turbine bucket material at 600°C in China. Structure stability study of Nimonic 80A shows its possibility of 700°C application for USC steam turbine buckets.
1