1-20 of 24 Search Results for

surgical implant applications

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Alloy Digest (1995) 44 (6): SS-596.
Published: 01 June 1995
... BioDur 316LS stainless steel is a modified version of Type 316L stainless steel to improve corrosion resistance for surgical implant applications. The alloy is vacuum arc remelted. This datasheet provides information on composition, physical properties, hardness, and tensile properties. It also...
Journal Articles
Alloy Digest (2005) 54 (1): SS-915.
Published: 01 January 2005
... drawn wire and bar. Bar can be round or billet. Standard sizes range from fine wire to 33 mm round. Other sizes are available on request. Strip is also available. Applications: This alloy has been used in implantable orthopedic components such as bone plates, bone screws, and hip and knee components...
Journal Articles
Alloy Digest (2014) 63 (10): SS-1186.
Published: 01 October 2014
... cleanliness (according to ASTM E45/A or ISO 4967 /A). See Table 2. Products Available: All products in bars, wire, and billet. Applications: Ugipure 4441 can be used to manufacture any surgical implant designed to remain for a long period of time or permanently in the human body: prosthesis, screw, plate, etc...
Journal Articles
Alloy Digest (2005) 54 (11): Ti-137.
Published: 01 November 2005
... 2005 ASM International ALLVAC 6Al-4V ELI chemical composition elasticity hardness heat treatability high-temperature alloys implant applications joinability low-temperature alloys machinability physical properties surgical instruments tensile properties workability thermal...
Journal Articles
Alloy Digest (2006) 55 (7): Ti-139.
Published: 01 July 2006
... that could adversely affect notch sensitivity and forming characteristics. Product Forms Available: Bar and billet Applications: This alloy was developed for medical devices and surgical implants such as total hip replacement systems, fracture fixation plates, intermedullary rods and nails, spinal...
Journal Articles
Alloy Digest (2017) 66 (4): Ti-159.
Published: 01 April 2017
... ATI 6-4 ELI, also known as Grade 23, is a higher purity grade of ATI Ti-6Al-4V for use in surgical and medical applications. This datasheet provides information on composition, physical properties, hardness, and tensile properties as well as fracture toughness. It also includes information on...
Journal Articles
Alloy Digest (2014) 63 (9): Ti-157.
Published: 01 September 2014
... Sandvik Bioline Ti6Al4V ELI is an alpha-beta titanium alloy used mainly for medical implant applications. It is an extra low interstitial alloy with a high purity, which confers improved ductility and fracture toughness. This datasheet provides information on composition, physical properties, and...
Journal Articles
Alloy Digest (1981) 30 (9): SS-392.
Published: 01 September 1981
... weldability and scales at approximately 1650OF. Forms Available: Bar, rod, wire and forging billets. Applications: Typical applications for CRUCIBLE 316L comprise screw- machine products, food-processing equipment, photographic developing equipment, machined shafts, pulphandling equip ment, surgical implants...
Journal Articles
Alloy Digest (2006) 55 (12): Co-115.
Published: 01 December 2006
... numerous applications in watch making, surgical implants, metrology, electronics, and aeronautical engineering. Other applications include springs for watch motors, shaped springs such as helical springs, flexible couplings, electrical and electronic apparatus, equipment for the chemical and oil and gas...
Journal Articles
Alloy Digest (2011) 60 (12): Co-24.
Published: 01 December 2011
... temperature and time, it perforated at the crevice site location. The alloy is acceptable for use in sour environments by qualifying with the NACE MR0175 sulfide cracking test; max hardness HRC is 35. The alloy also has been tested for pitting/crevice corrosion of surgical implants by the ASTM test F-746 (2...
Journal Articles
Alloy Digest (2020) 69 (12): Ti-173.
Published: 01 December 2020
.... Product Forms Bar, wire, plate, sheet, forging, welding filler metal. Applications Aerospace applications, automotive applications, jewelry, offshore applications, sonotrodes, surgical implants. Supplier Zapp AG Zapp-Platz 1 40880 Ratingen, Germany Tel: +49 2102 710 0 Web: www.zapp.com All data from Zapp...
Journal Articles
Alloy Digest (1991) 40 (2): Co-61.
Published: 01 February 1991
... (solution treated and cold drawn bars) AhIS 5845 (solution treated, cold drawn and aged bars) AMS 7468 (bolts and screws, forged head, roll threaded after aging) ANS/ASTM F562-78 (surgical implant applications) NACE Standard MR-01-75 (sulfide stress cracking resistant material for oil field equipment...
Journal Articles
Alloy Digest (2006) 55 (6): Co-111.
Published: 01 June 2006
... applications. Surgical implants constructed of Conichrome wire can be safely imaged using magnetic resonance imaging (MRI), without risk of migration and with minimal image degradation because of the nonmagnetic characteristics of the material. Specification Equivalents: ASTM F 1058 UNS R30003, R30008 ISO 5832...
Journal Articles
Alloy Digest (2020) 69 (4): Ti-165.
Published: 01 April 2020
... R50250) ISO 5832-2:2018(c) Grade 1 EN ISO 5832-2:2018(c) Grade 1 (a) For titanium and titanium alloy plate, sheet, and strip. (b) For titanium and tita- nium alloy wire. (c) For unalloyed titanium for surgical implant applications Table 1 Tensile properties at room temperature Tensile strength, min 0.2...
Journal Articles
Alloy Digest (2002) 51 (7): Ti-129.
Published: 01 July 2002
... (billet), AMS 4998 (powder), ASTM F 136 (wrought surgical implants), ASTM F 620 (forgings surgical implants), AWS A5.16-70 (weld filler wire rod) General Characteristics: Ti 6Al-4V ELI is a higher-purity (extra-low interstitial) version of Ti 6Al- 4V, with lower specified limits on iron and the...
Journal Articles
Alloy Digest (2005) 54 (7): Ti-136.
Published: 01 July 2005
... Forms Available: Bar, rod, sheet, and wire Applications: Typical applications are with orthopedic, trauma, spinal, and cardiovas- cular devices. References: 1. L. Zardiackas, D. Mitchell, and J. Disegi, Characterization of Ti-15Mo Alloy for Orthopaedic Implant Applications, Medical Applications of...
Journal Articles
Alloy Digest (1988) 37 (6): Ta-10.
Published: 01 June 1988
... chemicals Temperature Rate OC lO+Wyr 20 weight % HCl 190 2.29 200 3.30 220 22.90 37 weight B HCl 100 1.52 110 4.06 120 9.14 encountered in industry. It may be used as surgical implants without harm to the human body. It resists liquid metal attack. TANTALUM is attacked slowly by strong alkalies and more...
Journal Articles
Alloy Digest (2007) 56 (11): Ag-13.
Published: 01 November 2007
... more materials into a single wire or ribbon system. As a result of extreme compressive forces imparted during the processing of the dissimilar materials, the mechanical bond formed between surfaces has been found to be metallurgically sound. This feature has given rise to a number of novel applications...
Journal Articles
Alloy Digest (2021) 70 (4): Ti-177.
Published: 01 April 2021
... by stress relieving. Due to the low modulus of elasticity of titanium, springback allowances are significant. Hot sizing Applications in the chemical industry; marine applications; after cold forming is often used to correct for variations in medical implants; medical, surgical, and dental...
Journal Articles
Alloy Digest (1972) 21 (11): Ta-2.
Published: 01 November 1972
... cathodes; surgical implants and instruments. Manufacturerr Teledyne Wah Chang Albany Albany, Oregon 97321. Kawecki Berylco Industries, Inc. New York, N.Y. 10017. Fansteel, Inc. North Chicago, Illinois 60064. ...