1-20 of 27 Search Results for

bus conductors

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Alloy Digest (1970) 19 (1): Al-194.
Published: 01 January 1970
... Aluminum 6101 in the heat treated condition is used primarily for enclosed bus conductor where both high strength and high electrical conductivity are desirable. This datasheet provides information on composition, physical properties, hardness, elasticity, tensile properties, and shear strength...
Journal Articles
Alloy Digest (1988) 37 (3): Al-287.
Published: 01 March 1988
... UNS NO. A96101 in the heat treated condition is used primarily for enclosed bus conductor where both high strength and high electrical conductivity are desirable. This datasheet provides information on composition, physical properties, hardness, elasticity, tensile properties, and shear strength...
Journal Articles
Alloy Digest (1979) 28 (3): Cu-368.
Published: 01 March 1979
... Copper No. 102 is a wrought oxygen-free high-conductivity copper. Its trade designation is OF (Oxygen Free) copper. It can be fabricated by all the conventional methods and is used widely for bus bars, bus conductors and other electrical conductors. This datasheet provides information...
Journal Articles
Alloy Digest (1966) 15 (5): Al-155.
Published: 01 May 1966
... Aluminum 6101 is a heat treatable wrought alloy recommended for applications involving maximum electrical conductivity with moderately high strength, such as bus conductors. This datasheet provides information on composition, physical properties, hardness, elasticity, tensile properties, and shear...
Journal Articles
Alloy Digest (1971) 20 (2): Cu-226.
Published: 01 February 1971
... CDA COPPER 109 is a boron-deoxidized copper with excellent hot and cold working properties and excellent electrical conductivity. It responds to most common fabricating techniques and is used mostly for electrical and electronic applications, such as bus bars and conductors, cable shielding...
Journal Articles
Alloy Digest (2005) 54 (8): Al-396.
Published: 01 August 2005
... A96101 General Characteristics: Alloy 6101 is prominent in the line of bus conductor extruded products. As a heat treatable wrought alloy, it is best suited for applications involving moderate strength and maximum electrical conductivity. It is similar to alloy 6063, but with minor chemistry changes...
Journal Articles
Alloy Digest (2016) 65 (10): Cu-852.
Published: 01 October 2016
... machining characteristics. The machinability rating for C10200 is 20% of free- cutting brass. DOI: 10.31399/asm.ad.cu0852 Applications: Electrical: bus bars, bus conductors, and other electrical conductors; waveguides; welded tube; billet mold tubes; and coaxial cables and tubes Producers: Mueller Brass Co...
Journal Articles
Alloy Digest (1970) 19 (11): Cu-222.
Published: 01 November 1970
... Copper No. 110, generally known as electrolytic tough pitch copper or ETP, is cathode copper remelted and cast with a controlled oxygen content. It is the most important type of copper commercially available and is used by the electrical industry as wire for electrical conductors, bars for bus...
Journal Articles
Alloy Digest (2016) 65 (9): Cu-851.
Published: 01 September 2016
...: 10.31399/asm.ad.cu0851 Product Forms Available: Rod and bar Applications: Automotive: automotive rectifier (thermal and electrical conductivity). Electrical: transistor component bases, bus conductors, other electrical conductors, bus bars, anodes for vacuum tubes, waveguides, glass to metal seals...
Journal Articles
Alloy Digest (2020) 69 (1): Cu-903.
Published: 01 January 2020
... workability, high electrical and thermal conductivity, excellent brazeability and solderability, excellent corrosion resistance, freedom from hydrogen embrittlement. Product Forms Plate, sheet, strip, rolled bar. Applications Bus conductors, busbars, carrier tapes, coaxial cables, contacts and terminals...
Journal Articles
Alloy Digest (1988) 37 (5): Cu-538.
Published: 01 May 1988
... and tube, flat and conventional wire. Applications: Bus bars, bus conductors, and other conductors. wave guides, hollow conductors, lead-in wires and anodes for vacuum tubes, vacuum seals, transistor compon- ents, glass-to-metal seals, coaxial tubes. klystrons, micro-wave tubes and automotive rectifiers...
Journal Articles
Alloy Digest (1974) 23 (5): Cu-278.
Published: 01 May 1974
... solutions drastically damage its corrosion resistance. Forms Available: Bar, rod, plate, shapes, forgings, sheet, strip, tube, wave guides, wire, pipe and tube. Applications: Bus bars, bus conductors, and other conductors, wave guides, hollow conductors, lead-in wires and anodes for vacuum tubes, vacuum...
Journal Articles
Alloy Digest (1986) 35 (9): Cu-515.
Published: 01 September 1986
... No. C8llOO comprise electrical and thermal conductors; uses requiring resistance to corrosion and oxidation; bus conductor components and hollow conductors. Manufacturers: Copper foundries. ...
Journal Articles
Alloy Digest (1981) 30 (3): Cu-413.
Published: 01 March 1981
... it readily. Forms Available: Sand castings. Applications: Electrical and thermal conductors, bus conductor components, hollow conductors and uses requiring resistance to corrosion and oxidation. Manufacturer: Ampco Metal Division of Ampco-Pittsburgh Corporation Milwaukee, Wisconsin 53201. ...
Journal Articles
Alloy Digest (1986) 35 (3): Cu-507.
Published: 01 March 1986
..., centrifugal, continuous and investment. Applications: Electrical and thermal conductors; uses requiring resistance to corrosion and oxidation; bus conductor components and hollow conductors. Manufacturer: Copper foundries. ...
Journal Articles
Alloy Digest (1979) 28 (4): Cu-370.
Published: 01 April 1979
...: Electrical and thermal conductors; uses requiring resist- ance to corrosion and oxidation; bus conductor com- ponents and hollow conductors. Manufacturers: Copper foundries. ...
Journal Articles
Alloy Digest (2019) 68 (7): Al-458.
Published: 01 July 2019
... cylinder tubing, electrical bus conductors, and architectural applications. Producer Kaiser Aluminum Corporation Foothill Ranch, CA 92610, USA Tel: +1-949-614-1740 www.kaiseraluminum.com ISSN: 002-614X Al-458B Table 2 Comparative characteristics Temper Corrosion resistance Cold workability Machinability...
Journal Articles
Alloy Digest (1987) 36 (2): Cu-521.
Published: 01 February 1987
... Available: Castings: sand. plaster, permanent mold, centrifugal. continuous and investment. Applications: Copper No. C80100 is used where excellent electrical and thermal conductivity is required. Its other uses include those requiring resistance to corrosion and oxidation. It is also used for bus conductor...
Journal Articles
Alloy Digest (1990) 39 (3): Al-302.
Published: 01 March 1990
... AA 1350, formerly designated EC, is an electrical conductor grade aluminum. This datasheet provides information on composition, physical properties, elasticity, tensile properties, and shear strength as well as fatigue. It also includes information on forming, heat treating, machining, and joining...
Journal Articles
Alloy Digest (1991) 40 (6): Cu-561.
Published: 01 June 1991
..., piercing and punching, roll threading and knurling, shearing, spinning, squeezing and swaging, stamping. Forms Available: Flat products, rod, tubing, pipe, shapes Applications: Bus bars, electrical conductors, tubular bus. where good conductivity and joining characteristics are required. Producers: Copper...