1-20 of 25 Search Results for

biocompatibility

Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Alloy Digest (2014) 63 (10): Pt-6.
Published: 01 October 2014
... Sandvik Bioline Pt/Ir Alloys (Pt10Ir, Pt20Ir) are precious metal wires that combine excellent biocompatible properties with excellent radiopacity, moderate strength, and good formability. This datasheet provides information on composition, physical properties, hardness, and tensile properties...
Journal Articles
Alloy Digest (2001) 50 (12): Ti-123.
Published: 01 December 2001
... TIMETAL 367 is a Ti-6Al-7Nb medium-strength alpha-beta alloy for surgical implants. The alloy is analogous to TIMETAL 367 6-4 (revised as Ti-6Al-4V, Alloy Digest Ti-66, September 1992), but with niobium as the more biocompatible alloying element. This datasheet provides information on composition...
Journal Articles
Alloy Digest (2023) 72 (5): Ti-192.
Published: 01 May 2023
... ductility at cryogenic temperatures and its excellent biocompatibility with the human body. This datasheet provides information on composition, physical properties, elasticity, and tensile properties. It also includes information on corrosion resistance as well as forming, heat treating, machining...
Journal Articles
Alloy Digest (2006) 55 (7): Ti-139.
Published: 01 July 2006
... resorting to protective atmospheres. Corrosion Resistance: The diagram shown in Fig. 1 illustrates the relationship between polarization resistance and biocompatibility of pure metals, cobalt- chromium alloy, and stainless steels. Corrosion studies in saline solutions suggest that vanadium and iron...
Journal Articles
Alloy Digest (2002) 51 (7): Ti-129.
Published: 01 July 2002
... Carpenter titanium alloy Ti 6Al-4V ELI is a high-purity (extra-low-interstitial) version of Ti 6Al-4V (see Alloy Digest Ti-60, August 2002). The alloy is alpha plus beta and has good biocompatibility. This datasheet provides information on composition, physical properties, elasticity, tensile...
Journal Articles
Alloy Digest (2014) 63 (10): SS-1186.
Published: 01 October 2014
... Ugima Ugipure 4441 is a clean microstructure alloy for good biocompatibility. This datasheet provides information on composition, physical properties, microstructure, elasticity, and tensile properties. It also includes information on corrosion resistance as well as forming, heat treating...
Journal Articles
Alloy Digest (2021) 70 (6): Co-137.
Published: 01 June 2021
... Ugitech UGI Phynox is an austenitic cobalt-based alloy with a unique combination of high static and fatigue strength, excellent formability, and excellent corrosion resistance and biocompatibility. Its nonmagnetic characteristic is important for such devices as gyroscopes, chronoscopes...
Journal Articles
Alloy Digest (2021) 70 (8): Co-139.
Published: 01 August 2021
... Deloro Stellite 21 (UNS R30021), previously known as Stellite 8, is similar to the medical implant alloy ASTM F75. It is a Co-Cr- Mo-Ni alloy that was developed in the mid-1930s as a corrosion resistant alloy, and rapidly found application as a biocompatible hip implant and denture alloy...
Journal Articles
Alloy Digest (2005) 54 (7): Ti-136.
Published: 01 July 2005
... at exposed surfaces when performing machining, cutting, or grinding operations. Corrosion Resistance and Biocompatibility: The passive oxide film on the surface of titanium and titanium alloys is resistant to tarnish and corrosion and also contributes to biocompatibility and osseointegratability. A tenacious...
Journal Articles
Alloy Digest (2021) 70 (4): Ti-177.
Published: 01 April 2021
... and type of cold work- Biocompatibility ing. (b) High strengths can be achieved by cold working up to 95% total reduction. It can be achieved by repeated cold deformation up to approximately 50% followed by The biocompatibility of L. Klein Titan Grade 2 in the human stress relieving at 500 540 °C (930 1005...
Journal Articles
Alloy Digest (2022) 71 (4): Co-144.
Published: 01 April 2022
... Moderate Excellent Good Biocompatibility CarTech GADS Vitallium has been deployed for various implant applications in contact with both soft tissue and bone. Precedence of acceptability within the medical market has been established, and biocompatibility reports on the alloy are available within...
Journal Articles
Alloy Digest (2014) 63 (9): Ti-157.
Published: 01 September 2014
... Characteristics: The grade meets the stringent requirements of all applicable standards for implant materials. The alloy is characterized by: Excellent biocompatibility Good forgeability Advanced corrosion resistance High strength High purity High quality surface finish Products Available: Finishes...
Journal Articles
Alloy Digest (2020) 69 (12): Ti-173.
Published: 01 December 2020
... of oxygen (air or moisture) exists in the environment. Biocompatibility TiAl6V4 exhibits very good biological compatibility with human tissues and bones. For this reason, the alloy is used extensively for medical applications and in the jewelry industry. Hot Forming Conventional Forging. Heat to 980 °C...
Journal Articles
Alloy Digest (2018) 67 (3): Ti-160.
Published: 01 March 2018
... and commercially pure (CP) grades exhibit a high strength-to- weight ratio with excellent corrosion resistance and are biocompatible. Table 1 Chemical composition of Ancorti AncorTi Ti6AL4V Grade 5 AncorTi Ti6AL4V Grade 23 AncorTi Com- mercially Pure Grade 1 AncorTi Com- mercially Pure Grade 2 Aluminum 5.50 6.75...
Journal Articles
Alloy Digest (2006) 55 (6): Co-111.
Published: 01 June 2006
... thermal treatment. After annealing with a rapid quench, the alloy has a face-centered cubic structure. Biocompatibility: Although there is no universally accepted definition for bio- compatibility of biomaterials, a medical device should be safe for its intended use. Conichrome alloy has been employed...
Journal Articles
Alloy Digest (2007) 56 (11): Ag-13.
Published: 01 November 2007
... 0.001 99.4 30.3 41% Ag 0.006 2.17 0.663 0.004 15.2 1.64 0.002 21.5 6.57 0.001 86.3 26.3 Solid MP35N 0.006 54.1 16.5 0.004 122 37.1 0.002 489 149 0.001 1952 595 DOI: 10.31399/asm.ad.ag0013 Fig. 1 Example of DFT wire biocompatibility of implant grade alloys with desired properties of other materials...
Journal Articles
Alloy Digest (2021) 70 (1): Ti-174.
Published: 01 January 2021
.... Comparable Grades Arcam AB Arcam Ti6Al4V ASTM F2924:2014 Ti-6Al-4V General Characteristics Low density; high strength; outstanding corrosion resis- tance; excellent biocompatibility; good machinability; near- net shape. Product Forms Alloy powder; additively manufactured components. Applications...
Journal Articles
Alloy Digest (2020) 69 (4): Ti-165.
Published: 01 April 2020
... is biocompatible and exhibits excellent corrosion resistance in highly oxidizing to mildly reducing environments, including chlorides. Grade 1 can be used in continuous service up to 425 °C (795 °F) and in intermittent service up to 540 °C (1000 °F). Information on general characteristics has been sourced from M.J...
Journal Articles
Alloy Digest (2021) 70 (1): Co-132.
Published: 01 January 2021
... F75 CoCr parts produced using the Arcam EBM process exhibit fully dense parts without weld lines. There excellent biocompatibility; near-net shape; excellent feature is no porosity in the as-built material. Figures 2 and 3 show resolution; high polishability; excellent surface finish. the typical...
Journal Articles
Alloy Digest (2020) 69 (9): Ti-170.
Published: 01 September 2020
... in the environment. In general, the higher the purity of CP Ti, the greater the corrosion resistance. Biocompatibility Ti 1, Ti 2, Ti 3, and Ti 4 show a very good biological compatibility with human tissues and bones. This is the reason for the increasing demand for these grades in medical applications...